ebusd-configuration icon indicating copy to clipboard operation
ebusd-configuration copied to clipboard

How to get/write "RoomTempCorr" on VRC720?

Open rICTx-T1D opened this issue 7 months ago • 11 comments

Hi folks,

in files "015.e7c.csv" and other I found the following parameters: r;wi,,RoomTempCorr,Room Temp Correction,,,,3300,,,temp,,,Room Temp Correction r;wi,,OutsideTempCorr,Outside Temp Correction,,,,3600,,,temp,,,Outside Temp Correction

Now I try to read und write it from my vrc700 and and it in 15.ctlv2.csv and 08.hmu.csv. But it doesn't work. Because I can set the value in display as regular user, I think it must be possible to change it on ebusd.

With 3300 element was not found, with " r;wi,,RoomTempCorr,Room Temp Correction,,,,3300,,,temp,,,Room Temp Correction " element found but not valid position

hmu RoomTempCorrection = (ERR: invalid position for 3108b51403055700 / 00)

some info:

version: ebusd 23.3.23.3-70-gefcb0f3
update check: revision 23.3 available
device: 172.30.121.30:9999, TCP, enhanced, firmware 1.1[460f].1[460f]
access: *
signal: acquired
symbol rate: 61
max symbol rate: 150
min arbitration micros: 2
max arbitration micros: 13
min symbol latency: 5
max symbol latency: 48
scan: finished
reconnects: 0
masters: 5
messages: 227
conditional: 0
poll: 7
update: 8
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=HMU00;SW=0901;HW=5103"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=CTLV2;SW=0514;HW=1104"
address 31: master #8, ebusd
address 33: master #13
address 36: slave #8, ebusd
address 38: slave #13, scanned "MF=Vaillant;ID=V32;SW=0106;HW=6004", loaded "vaillant/38.v32.csv"
address 71: master #9
address 76: slave #9, scanned "MF=Vaillant;ID=VWZIO;SW=0902;HW=5103", loaded "vaillant/76.vwzio.csv"

Hope anyone has some idea. Bye, RICT

rICTx-T1D avatar Jul 21 '24 13:07 rICTx-T1D