ebusd-configuration icon indicating copy to clipboard operation
ebusd-configuration copied to clipboard

Vaillant Recovair 260/4 - Ventilation Boost Mode

Open pphlwmarcel opened this issue 2 years ago • 0 comments

Hey,

I've got my Vaillant Recovair 260/4 with a VRC700 Multimatic. The Recovair is behind a V32, because the heating is also connected to the ebus. I've found the csv-file for the recovair and used it (by renaming it to 38.v32.csv and it's working fine.

Unfortunately there is no function to activate Ventilation Boost Mode.

I was able to capture the stuff that is happening on ebus when activating the Ventilation Boost on VRC700 but I haven't found out how to interpret these messages. Maybe anyone here can help me with that?

2023-02-17 14:33:21.818 [update notice] received unknown MS cmd: 1038b50903298603 / 0486030080
2023-02-17 14:33:22.161 [update notice] received unknown MS cmd: 1038b50903298703 / 0487030080
2023-02-17 14:33:22.507 [update notice] received unknown MS cmd: 1038b50903298803 / 0488030080

This is my config file: 38.v32.csv

I found out that 2023-02-17 15:51:11.238 [update notice] received unknown MS cmd: 1038b50903298803 / 0488030080 is resoved to that, but that doesn't help me a lot. 2023-02-17 16:02:48.612 [update notice] received write v32 FanLevelDay QQ=10: 4

pphlwmarcel avatar Feb 17 '23 16:02 pphlwmarcel