Added ManualCooling and GlobalSystemOff to VRC-700
Adds ManualCooling and GlobalSytemOff when VRC 700 is used.
- The config line for
ManualCoolingwas largely inspired by kolibrie-eric:PR1 (currently in Draft state), with minor fixup and translation, so credit goes to @kolibrie-eric. - The line for
GlobalSystemOffwas discovered using the steps described in the wiki usinggrabandgrab result. The wording was taken from file 15.370.csv (incl. the confusing fact that you have to send an ON in order to turn the system OFF)
Both lines, including the hex instructions, I could also see while grabbing instructions sent by the Vaillant "multiMATIC" app (via VR920).
E.g. when choosing "System AUS" in the multimatic app I grabbed these messages:
1076b512030f0001 / 07b8030000801203 = 1
0015b52406020000007800 / 06030078000a00 = 2
0015b52406020003001b00 / 0601031b000a00 = 1
0015b5240702010000070001 / 020000 = 1
1076b51009000000ffffff050000 / 0101 = 1
whereas when aborting that state (= powering system ON again) I found these messages on the bus:
1076b512030f0001 / 07ba030000801203 = 1
0015b52406020000000700 / 050300070000 = 1
0015b52406020003001b00 / 0601031b000000 = 1
0015b5240702010000070000 / 020000 = 1
1076b51009000000ffffff010000 / 0101 = 1