ebusd-configuration icon indicating copy to clipboard operation
ebusd-configuration copied to clipboard

No Models found

Open ChaotY2k opened this issue 7 years ago • 7 comments

Hello,

I have a VRC700 with serial ebusd-converter on a raspberry 3B+ at GPIO.

Thats my ebusctl i:

version: ebusd 3.2.v3.2-11-g18bd21f signal: acquired symbol rate: 21 max symbol rate: 62 reconnects: 0 masters: 2 messages: 12 conditional: 0 poll: 0 update: 4 address 10: master #2 address 31: master #8, ebusd address 36: slave #8, ebusd

thats the local log: 2018-10-10 19:18:25.248 [bus notice] <1008b5110100480011ff5600ff5700 2018-10-10 19:18:25.538 [bus notice] <1008b53dff040000af01019a00 2018-10-10 19:18:35.275 [bus notice] <09480011ff5400ffeb00 2018-10-10 19:18:35.562 [bus notice] <10b5100900003dffff040000af000101 2018-10-10 19:18:35.835 [bus notice] <10b51101028a00033c964682 2018-10-10 19:18:45.300 [bus notice] <08b51101018900480011ff5400ffeb00 2018-10-10 19:18:45.588 [bus notice] <1008b51009000078ffff040000af019a00 2018-10-10 19:18:55.333 [bus notice] <08b51101018909480011ff540000 2018-10-10 19:18:55.623 [bus notice] <1008b5100900003dffff040000af019a00 2018-10-10 19:19:05.325 [bus notice] <1008b5110101480011ff540000ffeb 2018-10-10 19:19:05.622 [bus notice] <10b50401003d000305191910101800 2018-10-10 19:19:05.856 [bus notice] <10b5160800061910100318b0 2018-10-10 19:19:06.183 [bus notice] <7800019a00 2018-10-10 19:19:06.453 [bus notice] <08b511010200033c96468220 2018-10-10 19:19:06.734 [bus notice] <08b5110100880216000000012600 2018-10-10 19:19:06.995 [bus notice] <1008b5100305ff01000000 2018-10-10 19:19:07.244 [bus notice] <08b51202000000 2018-10-10 19:19:07.506 [bus notice] <08b5120204ff019a00 2018-10-10 19:19:07.732 [bus notice] <10feb516030100cd 2018-10-10 19:19:15.371 [bus notice] <1008b5110101090011ff5400ffeb00 2018-10-10 19:19:15.657 [bus notice] <08b5100900003dff040000af01019a00 2018-10-10 19:19:25.394 [bus notice] <1008b511010189090011ff5400ffeb00 2018-10-10 19:19:25.680 [bus notice] <08b5100900003dffff040000af01019a00 2018-10-10 19:19:35.400 [bus notice] <10081101018909460011ff540000eb00 2018-10-10 19:19:35.692 [bus notice] <10b5100900003d78ff040000af00010100 2018-10-10 19:19:36.007 [bus notice] <10b51101028a00033c9646822000

ChaotY2k avatar Oct 10 '18 17:10 ChaotY2k

ok, and what exactly do you want with this issue?

john30 avatar Oct 14 '18 16:10 john30

I dont understand why I dont see the VRC700 or any message. I‘ve tried local and online csv, but no luck. I see the aa if I enable the byte debug.

ChaotY2k avatar Oct 16 '18 13:10 ChaotY2k

is your ebusd-converter able to write to the bus?

john30 avatar Oct 19 '18 07:10 john30

Hi, yes... it is the ESRA RS232

ChaotY2k avatar Oct 19 '18 08:10 ChaotY2k

do you know that writing works? try sending a hex message like this: ebusctl hex 08070400 (you might need to enable the hex command before by adding the --enablehex argument to the start of ebusd)

john30 avatar Oct 20 '18 15:10 john30

what happens if the answer for ebusctl hex 08070400 ist ERR read timeout ?

cbeham avatar Nov 12 '19 17:11 cbeham

then either your boiler isn't willing to answer or your device can't write

john30 avatar Nov 16 '19 08:11 john30