Please add macros for X-axis_twist_compensation

Open PhilBaz opened this issue 1 year ago • 2 comments

Please add macros for X-axis_twist_compensation

https://github.com/Klipper3d/klipper/pull/6624#issuecomment-2420026334

PhilBaz avatar Oct 17 '24 16:10 PhilBaz

Hi, it seems that it's necessary to grab the probe before doing the AXIS_TWIST_COMPENSATION_CALIBRATE, can you confirm that's the case?

jlas1 avatar Oct 17 '24 21:10 jlas1

@jlas1

I haven't tried that my self but I believe I did see Sineos say that on Klipper discourse...Ahh found it.

https://klipper.discourse.group/t/feature-request-dockable-probe-support-for-axis-twist-compensation/11744

PhilBaz avatar Oct 18 '24 01:10 PhilBaz

Hi, it seems that it's necessary to grab the probe before doing the AXIS_TWIST_COMPENSATION_CALIBRATE, can you confirm that's the case?

I tried to setup axis-twist-compensation, however, the probe nor the z endstop stop the printhead from moving down. I think there is more work to be done than just attaching the probe...

Edit:

Okay, so after looking at clippers source, I figured it out:

klickys variable_safe_z does not override the safe-z-height used for axis_twist_compensation. To mitigate this, one can manually specify horizontal_move_z: <High number (eg. 50)> in the [axis_twist_compensation]-section

Afterward, I performed the axis-twist-calibration perfectly fine. When manually touching the nozzle to the bed, I detached the probe, and while the printer got back up to Z=50, i manually re-attached the klicky with my hands.

TL;DR:

  • specify horizontal_move_z: <High number (eg. 50)>in the [axis_twist_compensation]-section
  • attach probe before runnign the command
  • detach probe after probing
  • adjust-nozzle / confirm
  • attach probe

Also:

Users please don't comment anything out like in the linked thread(!)

Alia5 avatar Dec 07 '24 17:12 Alia5