Hello, could you please implement Voltronic Hybrid 10K Inverter?

All information about this could be found here: https://github.com/riogrande75/infinipoll10k

Thank you and regards,

Chris

cbr303 avatar Feb 14 '22 07:02 cbr303

Have you tried PI17 protocol?

jblance avatar Feb 14 '22 20:02 jblance

Hi John,

yes, 10K speaks P17. Here ist the output from the get commands, I did not test all set commands for now. There appear some „unknown“ answers and ET is rejected which may happen because its zero in the device, but there is no error in SolarPower wich correctly shows "0".

Have a look at infinipoll10k: INGS, RTCP, EMINFO could be implemented for P17 and ^P014EDyyyymmddnnn: Query generated energy of day, ^P016EHyyyymmddhhnnn: Query generated energy of hour, to get infos for day and hourly produced energy.

root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c PI
Command: PI - Device Protocol Version inquiry
------------------------------------------------------------
Parameter                     	Value           Unit
protocol_version              	17             	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c ID
Command: ID - Device Serial Number inquiry
------------------------------------------------------------
Parameter                     	Value           Unit
serial_number                 	1496162107100016000000	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c VFW
Command: VFW - Device CPU version inquiry
------------------------------------------------------------
Parameter                     	Value           Unit
cpu_version                   	VERFW:00001.01 	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c VFW2
Command: VFW2 - Device CPU 2 version inquiry
------------------------------------------------------------
Parameter                     	Value           Unit
cpu_2_version                 	VERFW2:00001.01	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c MD
Command: MD - Device Model inquiry
------------------------------------------------------------
Parameter                     	Value           Unit
machine_number                	Infini-Solar 10KW/3P	    
output_rated_va               	10000          	kW  
output_power_factor           	99             	pf  
ac_input_phase_number         	3              	number
ac_output_phase_number        	3              	number
norminal_ac_output_voltage    	2300           	0.1V
norminal_ac_input_voltage     	2300           	0.1V
battery_piece_number          	04             	ea  
battery_standard_voltage_per_unit	120            	0.1V
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c PIRI
Command: PIRI - Device rated information
------------------------------------------------------------
Parameter                     	Value           Unit
ac_input_rated_voltage        	2300           	0.1V
ac_input_rated_frequency      	500            	Hz  
ac_input_rated_current        	0434           	0.1A
ac_output_rated_voltage       	2300           	0.1V
ac_output_rated_current       	0434           	0.1A
mppt_rated_current_per_string 	0187           	0.1A
battery_rated_voltage         	0480           	0.1V
mppt_track_number             	2              	ea  
machine_type                  	Hybrid type    	    
topology                      	transformerless	    
parallel_for_output           	enabled        	    
unknown_value_in_response_11  	0              	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c GS
Command: GS - Device rated information
------------------------------------------------------------
Parameter                     	Value           Unit
solar_input_voltage_1         	0              	0.1V
solar_input_voltage_2         	0              	0.1V
solar_input_current_1         	0              	0.1A
solar_input_current_2         	0              	0.1A
battery_voltage               	0              	0.1V
battery_capacity              	0              	%   
battery_current               	0              	0.1A
ac_input_voltage_r            	2318           	0.1V
ac_input_voltage_s            	2298           	0.1V
ac_input_voltage_t            	2309           	0.1V
ac_input_frequency            	4983           	0.01Hz
ac_input_current_r            	0              	0.1A
ac_input_current_s            	0              	0.1A
ac_input_current_t            	0              	0.1A
ac_output_voltage_r           	0              	0.1V
ac_output_voltage_s           	0              	0.1V
ac_output_voltage_t           	0              	0.1V
ac_output_frequency           	0              	0.01Hz
ac_output_current_r           	               	0.1A
ac_output_current_s           	               	0.1A
ac_output_current_t           	               	0.1A
inner_temperature             	24             	°C  
component_max_temperature     	24             	°C  
external_battery_temperature  	0              	°C  
setting_change_bit            	Settings changed - please refresh	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c PS
Command: PS - Device Power Status
------------------------------------------------------------
Parameter                     	Value           Unit
solar_input_power_1           	0              	W   
solar_input_power_2           	0              	W   
battery_power                 	               	W   
ac_input_active_power_r       	0              	W   
ac_input_active_power_s       	0              	W   
ac_input_active_power_t       	0              	W   
ac_input_total_active_power   	0              	W   
ac_output_active_power_r      	0              	W   
ac_output_active_power_s      	0              	W   
ac_output_active_power_t      	0              	W   
ac_output_total_active_power  	0              	W   
ac_output_apparent_power_r    	0              	VA  
ac_output_apparent_power_s    	0              	VA  
ac_output_apparent_power_t    	0              	VA  
ac_output_total_apparent_power	0              	VA  
ac_output_power_percentage    	0              	%   
ac_output_connect_status      	Disconnected   	    
solar_input_1_work_status     	Idle           	    
solar_input_2_work_status     	Idle           	    
battery_power_direction       	Idle           	    
dc/ac_power_direction         	Idle           	    
line_power_direction          	Idle           	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c MOD
Command: MOD - Device working mode inquiry
------------------------------------------------------------
Parameter                     	Value           Unit
working_mode                  	Fault mode     	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c WS
Command: WS - Warning status inquiry
------------------------------------------------------------
Parameter                     	Value           Unit
solar_input_1_loss            	1              	bool
unknown_value_in_response_1   	1              	    
unknown_value_in_response_2   	0              	    
unknown_value_in_response_3   	0              	    
unknown_value_in_response_4   	0              	    
unknown_value_in_response_5   	0              	    
unknown_value_in_response_6   	1              	    
unknown_value_in_response_7   	0              	    
unknown_value_in_response_8   	1              	    
unknown_value_in_response_9   	0              	    
unknown_value_in_response_10  	0              	    
unknown_value_in_response_11  	0              	    
unknown_value_in_response_12  	0              	    
unknown_value_in_response_13  	0              	    
unknown_value_in_response_14  	0              	    
unknown_value_in_response_15  	0              	    
unknown_value_in_response_16  	0              	    
unknown_value_in_response_17  	0              	    
unknown_value_in_response_18  	0              	    
unknown_value_in_response_19  	0              	    
unknown_value_in_response_20  	0              	    
unknown_value_in_response_21  	0              	    
unknown_value_in_response_22  	               	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c FLAG
Command: FLAG - Query enable/disable flag status
------------------------------------------------------------
Parameter                     	Value           Unit
mute_buzzer_beep              	Enabled        	    
mute_buzzer_beep_in_standby_mode	Disabled       	    
mute_buzzer_beep_only_on_battery_discharged_status	Disabled       	    
generator_as_ac_input         	Disabled       	    
wide_ac_input_range           	Disabled       	    
n/g_relay_function            	Disabled       	    
unknown_value_in_response_6   	0              	    
unknown_value_in_response_7   	0              	    
unknown_value_in_response_8   	1              	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c T
Command: T - Query current time
------------------------------------------------------------
Parameter                     	Value           Unit
datetime                      	20220214220325 	YYYYMMDDHHMMSS
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c ET
Command: ET - Query total generated energy
------------------------------------------------------------
Parameter                     	Value           Unit
warning0                      	Command ET was rejected	    
root@solar:~# mpp-solar -p /dev/hidraw0 -P PI17 -c BATS
Command: BATS - Query battery setting
------------------------------------------------------------
Parameter                     	Value           Unit
battery_maximum_charge_current	600            	0.1A
battery_constant_charge_voltage(c.v.)	560            	0.1V
battery_floating_charge_voltage	540            	0.1V
battery_stop_charger_current_level_in_floating_charging	0              	0.1A
keep_charged_time_of_battery_catch_stopped_charging_current_level	60             	Minutes
battery_voltage_of_recover_to_charge_when_battery_stop_charger_in_floating_charging	530            	0.1V
battery_under_voltage         	420            	0.1V
battery_under_voltage_release 	480            	0.1V
battery_weak_voltage_in_hybrid_mode	480            	0.1V
battery_weak_voltage_release_in_hybrid_mode	540            	0.1V
battery_type                  	Li-Fe          	    
reserved                      	               	    
battery_install_date          	               	YYYYMMDDHHMMSS
ac_charger_keep_battery_voltage_function_enable/diable	Disabled       	    
ac_charger_keep_battery_voltage	480            	0.1V
battery_temperature_sensor_compensation	0              	0.m1V
max._ac_charging_current      	600            	0.1A
battery_discharge_max_current_in_hybrid_mode	300            	A   

Greets Christoph

cbr303 avatar Feb 14 '22 22:02 cbr303

ok will look at creating a copy of the pi17 protocol and try to implement fixes for the above issues ET might be more problematic, let me think about that one

jblance avatar Feb 17 '22 20:02 jblance

Hey John, thanks a lot for this

cbr303 avatar Feb 18 '22 20:02 cbr303

@cbr303 I have added those new commands INGS, RTCP, EMINFO in my fork here https://github.com/skoky/mpp-solar/tree/p17_new_commands and it seems to work on my InfiniSolar 10k as well. Anyway those are not documented anywhere in specs. Will improve results parsing and make pull request to @jblance for merging

skoky avatar Apr 25 '22 18:04 skoky

I have implemented those undocumented commands INGS, RTCP, EMINFO Not sure how to name response params, suggest change if you wish. Commands to query energy seems to work on mine

pi@raspi4:~/mpp-solar $ sudo  mpp-solar -p /dev/hidraw0 -P PI17  -c ET
Command: ET - Query total generated energy
------------------------------------------------------------
Parameter                     	Value           Unit
generated_energy              	11131          	kWh 

or

pi@raspi4:~/mpp-solar $ sudo  mpp-solar -p /dev/hidraw0 -P PI17  -c ED20211111 
Command: ED20211111 - Query generated energy of day
------------------------------------------------------------
Parameter                     	Value           Unit
generated_energy              	885            	Wh  

When using ET commands, do not use nnn, it is calculated in the code