LCR icon indicating copy to clipboard operation
LCR copied to clipboard

Measurement results off by a factor of 1.5 after calibration

Open wocard2 opened this issue 1 year ago • 2 comments

In the schematic, reference resistor R9 has a value of 1 kΩ, in the source code (lines 587 and 588 of Frontend.cpp), a value of 1.5 kΩ is used for the reference resistor.

wocard2 avatar Jan 26 '24 13:01 wocard2

Calibration resistor, not reference resistor. Sorry.

wocard2 avatar Jan 26 '24 16:01 wocard2

This is likely just a result of part availability when I built my device. My guess is that I wanted to use a 1 kΩ but it wasn't available when I ordered the parts, so I changed to 1.5 kΩ and forgot to adjust the schematic

jankae avatar Jan 26 '24 19:01 jankae