ioBroker.hm-rpc
ioBroker.hm-rpc copied to clipboard
RPC - HMIP-FWI: Fehler "warn State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20""
Describe the bug The RPC adapter returns periodic error messages from HMIP-FWI, which are as follows. There was no user input at the time
2022-07-01 06:26:23.990 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20"
2022-07-01 07:42:24.911 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20"
2022-07-01 05:30:41.622 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20"
2022-07-01 03:43:41.546 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20"
2022-07-01 01:57:10.515 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20
To Reproduce Install as below. iobroker on ccu2 with HMIP-FWI, no user input necessary, repeated occurrence of the above error message
Expected behavior no error message, clean processing of the value 31
Screenshots & Logfiles



2022-07-01 06:26:23.990 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20"
2022-07-01 07:42:24.911 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20"
2022-07-01 05:30:41.622 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20"
2022-07-01 03:43:41.546 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20"
2022-07-01 01:57:10.515 - warn: hm-rpc.3 (3701) State value to set for "hm-rpc.3.002BDD89B07938.0.CODE_ID" has value "31" greater than max "20"
Versions:
- hm-rpc version: <1.15.12>
- hm-rega version: <3.0.40>
- JS-Controller version: <cant't find it>
- NODE.JS: V14.19.1
- Operating system: <Linux>
- CCU model: <CCU2>
- CCU firmware: <2.61.7>
Additional context Add any other context about the problem here.
Just got the same problem. The problem is that after reading a correct value, the code ID 31 is ALWAYS sent automatically after a few seconds:
have nearly the same issue with the hm ip keypad
| hm-rpc.0 | 2022-07-27 22:58:28.805 | warn | State value to set for "hm-rpc.0.002E9F2990B473.0.CODE_ID" has value "32" greater than max "8" |
|---|
I am experiencing some kind of similar issues with: Thermostat "HmIP-eTRV-C" and a corresponding heating-group.
`
| hm-rpc.3 | 2022-08-01 07:48:07.402 | warn | State value to set for "hm-rpc.3.INT0000003.1.ACTIVE_PROFILE" has value "8" greater than max "3" |
|---|---|---|---|
| hm-rpc.2 | 2022-08-01 07:48:07.175 | warn | State value to set for "hm-rpc.2.000A9D898F8F44.1.ACTIVE_PROFILE" has value "8" greater than max "6" |
| hm-rpc.3 | 2022-08-01 07:48:04.475 | warn | State value to set for "hm-rpc.3.INT0000003.1.ACTIVE_PROFILE" has value "8" greater than max "3" |
| hm-rpc.2 | 2022-08-01 07:48:04.306 | warn | State value to set for "hm-rpc.2.000A9D898F8F44.1.ACTIVE_PROFILE" has value "8" greater than max "6" |
| hm-rpc.3 | 2022-08-01 07:40:49.788 | warn | State value to set for "hm-rpc.3.INT0000003.1.ACTIVE_PROFILE" has value "8" greater than max "3" |
| hm-rpc.2 | 2022-08-01 07:40:49.544 | warn | State value to set for "hm-rpc.2.000A9D898F8F44.1.ACTIVE_PROFILE" has value "8" greater than max "6" |
| hm-rpc.3 | 2022-08-01 07:33:47.845 | warn | State value to set for "hm-rpc.3.INT0000005.1.ACTIVE_PROFILE" has value "8" greater than max "3" |
| hm-rpc.3 | 2022-08-01 07:30:04.046 | warn | State value to set for "hm-rpc.3.INT0000003.1.ACTIVE_PROFILE" has value "8" greater than max "3" |
| hm-rpc.3 | 2022-08-01 07:30:03.631 | warn | State value to set for "hm-rpc.3.INT0000003.1.ACTIVE_PROFILE" has value "8" greater than max "3" |
| hm-rpc.2 | 2022-08-01 07:30:03.355 | warn | State value to set for "hm-rpc.2.000A9D898F8F44.1.ACTIVE_PROFILE" has value "8" greater than max "6" |
| hm-rpc.3 | 2022-08-01 07:01:56.338 | warn | State value to set for "hm-rpc.3.INT0000003.1.ACTIVE_PROFILE" has value "8" greater than max "3" |
I do also have the same issue. Devices are Wiegand interface and Keypad
| hm-rpc.0 | 2022-10-24 06:34:04.414 | warn | State value to set for "hm-rpc.0.002E9F299924D8.0.CODE_ID" has value "32" greater than max "8" |
|---|---|---|---|
| hm-rpc.0 | 2022-10-24 05:58:37.214 | warn | State value to set for "hm-rpc.0.002BDF298FF3EB.0.CODE_ID" has value "31" greater than max "20" |
| hm-rpc.0 | 2022-10-24 04:47:39.071 | warn | State value to set for "hm-rpc.0.002E9F299924D8.0.CODE_ID" has value "32" greater than max "8" |
| hm-rpc.0 | 2022-10-24 04:11:13.967 | warn | State value to set for "hm-rpc.0.002BDF298FF3EB.0.CODE_ID" has value "31" greater than max "20" |
| hm-rpc.0 | 2022-10-24 03:38:53.698 | warn | State value to set for "hm-rpc.0.002BDF298FF3EB.0.CODE_ID" has value "31" greater than max "20" |
@Ondastm can you provide the ioBroker object of hm-rpc.3.002BDD89B07938.0.CODE_ID
@foxriver76 Hallo, ich kann es auch bereitstellen, was genau brauchst du für Infos vom Objekt:

{ "type": "state", "common": { "name": "Haustuer_Wiegand_0.CODE_ID", "role": "", "def": 1, "type": "number", "read": true, "write": true, "min": 1, "max": 40, "custom": { "history.0": { "enabled": true, "aliasId": "", "changesOnly": true, "debounce": "1000", "changesRelogInterval": "0", "changesMinDelta": "0", "maxLength": "960", "retention": "0" } } }, "native": { "MIN": 1, "OPERATIONS": 7, "MAX": 20, "FLAGS": 1, "ID": "CODE_ID", "TYPE": "INTEGER", "DEFAULT": 1, "CONTROL": "MAINTENANCE.CODE_ID" }, "_id": "hm-rpc.1.002BD298BB50.0.CODE_ID", "acl": { "object": 1636, "state": 1636, "owner": "system.user.admin", "ownerGroup": "system.group.administrator" }, "from": "system.adapter.admin.0", "user": "system.user.admin", "ts": 1657181204416 }