indi icon indicating copy to clipboard operation
indi copied to clipboard

Celestron Driver causing CGE error 16/17

Open Swizerlan opened this issue 3 years ago • 2 comments

When I issue a goto command from Asi Air Plus to my cge via nexstar + usb port it causes the hc to say error 16 and 17. Then it slews until it hits the motor stop. I do not have these issues if I use a pc through the usb port via cpwi and nexremote.

To Reproduce

Initialize cge with asi air off, perform quick align. Plug cge nexstar+ usb up to asi air usb out. select the celestron cge driver, connect.

issue a goto command from asi air, this immediately triggers error 16 or 17.

Mc firmware 5.20 Hc firmware 5.31.9200

Expected behavior Commands sent from asi air using celestron indy driver should issue goto and plate solves without throwing error 16&17

Swizerlan avatar Feb 10 '22 13:02 Swizerlan

Hmmm I don't think a driver can cause that. These errors are usually from HC communication issues.

knro avatar Feb 10 '22 17:02 knro

Hmmm I don't think a driver can cause that. These errors are usually from HC communication issues.

I have tried 2 different HC’s with identical results. It only happens when I use asi air. I need to test the indi drivers via a pc connection tonight. I will have to load up linux though. If you or anyone else can test on a CGE that would help alot

Swizerlan avatar Feb 10 '22 17:02 Swizerlan

Any update on the PC tests?

knro avatar Nov 22 '22 06:11 knro

Yes and I apologize for not closing this out. A usb ground loop isolator between asi air and the nexstar controler fixed the problem

Swizerlan avatar Nov 22 '22 11:11 Swizerlan