console
console copied to clipboard
EU868 channel mask ack message
-
Are you using Helium hosted Console or running your own open source Console? Nova
-
If you are on Helium hosted Console, which url are you currently on? https://console-vip.helium.com/
-
If you are experiencing bugs in Helium hosted Console, please specify your Organization name and Device ID (ex. 3483050b-284d-47e2-8eda-e087fc03a753).
8bd91ec2-bee2-4d26-8848-d5edd221f225
Please describe your issue:
Several of my devices (with ADR enabled) are stuck in a loop whereby console sends a downlink after every uplink because my devices do not send a channel mask ack.

I can see the following in the downlink, channel mask is set to 255
category "downlink"
data
devaddr "64080048"
fcnt 21
hotspot {…}
integration {…}
mac
0
channel_mask 255
channel_mask_control 0
command "link_adr_req"
data_rate 5
number_of_transmissions 0
tx_power
And I get the following in the next uplink
category "uplink"
data
dc {…}
devaddr "64080048"
fcnt 40
hold_time 0
hotspot {…}
mac
0
channel_mask_ack 0
command "link_adr_ans"
data_rate_ack 1
power_ack 1
I'm in EU868 if that makes any difference. Device downlinks are received, and the ack for data_rate & power get sent OK every time