console icon indicating copy to clipboard operation
console copied to clipboard

EU868 channel mask ack message

Open Net-Metrics opened this issue 2 years ago • 0 comments

  1. Are you using Helium hosted Console or running your own open source Console? Nova

  2. If you are on Helium hosted Console, which url are you currently on? https://console-vip.helium.com/

  3. If you are experiencing bugs in Helium hosted Console, please specify your Organization name and Device ID (ex. 3483050b-284d-47e2-8eda-e087fc03a753).

8bd91ec2-bee2-4d26-8848-d5edd221f225

Please describe your issue:

Several of my devices (with ADR enabled) are stuck in a loop whereby console sends a downlink after every uplink because my devices do not send a channel mask ack.

image

I can see the following in the downlink, channel mask is set to 255

category	"downlink"
data	
devaddr	"64080048"
fcnt	21
hotspot	{…}
integration	{…}
mac	
0	
channel_mask	255
channel_mask_control	0
command	"link_adr_req"
data_rate	5
number_of_transmissions	0
tx_power

And I get the following in the next uplink

category	"uplink"
data	
dc	{…}
devaddr	"64080048"
fcnt	40
hold_time	0
hotspot	{…}
mac	
0	
channel_mask_ack	0
command	"link_adr_ans"
data_rate_ack	1
power_ack 1

I'm in EU868 if that makes any difference. Device downlinks are received, and the ack for data_rate & power get sent OK every time

Net-Metrics avatar Nov 14 '22 20:11 Net-Metrics