Hervé Bitteur
Hervé Bitteur
If I understand correctly this option: 1. Flag any voice that starts after measure start 2. Flag any voice that stops before measure stop Problem with second item is that...
> * **The line above the 1st ending was detected as a new 1-line staff** (!!), and the little vertical line segment at the left end of the 1st ending...
Oops, my mistake! The false staff between staves 1 and 2 on the right side is fixed. And your message is about the left side between staves 2 and 3,...
For the time being and to move forward, we simply increase constant minStaffLength from 30 (interlines) to 40 using the `Tools | Options` dialog
> * All of the x heads and stems on the space above the top line in the 4th (actual) D.Set staff, starting at bar 22, were discarded (even though...
Now I can see the false system 4, located just above the D.Set staff. It does look like a rather long 1-line staff. For the time being, I put minStaffLength...
We need to think about a solution for the long 1-line pseudo staff. Meanwhile, I will start working on multi-measure rests, something already asked by other users.
> I wonder if the engine can recognize the combination of lines above a volta: there's a long horizontal line, with a short vertical "hook" extending down from its left...
This minStaffLength is just part of the protection. I need to work on something more robust. Give me some time.
Sorry, I don't understand what you are trying to do.