Wrong windDirectionVertical (AC)
Logger: custom_components.hon.device Source: custom_components/hon/device.py:155 integration: hOn (documentation, issues) First occurred: 09:03:24 (1 occurrences) Last logged: 09:03:24
Unable to update parameter [windDirectionVertical] with value [3] because not in range ['2', '4', '5', '6', '7', '8']. Use default instead.
That's in line with the parameters retrieved via guide
Parameters: screenDisplayStatus: [0 - 1] - Default: 1 - Step: 1 echoStatus: [0 - 1] - Default: 0 - Step: 1 tempSel: [16 - 30] - Default: 22 - Step: 1 machMode: [0, 1, 2, 4, 6] - Default: 0 10degreeHeatingStatus: [0 - 1] - Default: 0 - Step: 1 silentSleepStatus: [0 - 1] - Default: 0 - Step: 1 muteStatus: [0 - 1] - Default: 0 - Step: 1 rapidMode: [0 - 1] - Default: 0 - Step: 1 healthMode: [0, 1] - Default: 0 humanSensingStatus: [0 - 3] - Default: 0 - Step: 1 selfCleaning56Status: [0 - 1] - Default: 0 - Step: 1 selfCleaningStatus: [0 - 1] - Default: 0 - Step: 1 windSpeed: [1, 2, 3, 5] - Default: 5 windDirectionVertical: [2, 4, 5, 6, 7, 8] - Default: 5 windDirectionHorizontal: [0, 3, 4, 5, 6, 7] - Default: 0
So don't use 3 as it's not valid.
I don't know what 3 means, but that setting comes automatically from my AC.
The value 3 is the 'HEALTH_LOW' position. Haier recently removes all data related to Health Mode for devices not supporting it.
When do you receive this error?
I'm not sure when this occurs. The error showed up after HA restart. The air conditioning must have been in some setting at that moment,
I also get this after a restart but with a 0 value:
This error originated from a custom integration.
Logger: custom_components.hon.device Source: custom_components/hon/device.py:155 integration: hOn (documentation, issues) First occurred: 12:05:01 (1 occurrences) Last logged: 12:05:01
Unable to update parameter [windDirectionVertical] with value [0] because not in range ['2', '4', '5', '6', '7', '8']. Use default instead.
And my device have "Health mode" - Haier Jade
Have you managed to resolve the issue?
I can definitely set the HEALTH_LOW and HEALTH_HIGH settings via remote, and if selected in the official hOn app the direction is updated to "health air flow" immediatly (However i cannot find an option to set it directly via hOn app).
I've tried to use the send custom request, but I'm struggling with the action code format.