Greg Miller

Results 107 issues of Greg Miller

This will make our functions easier to read. https://peps.python.org/pep-0484/

documentation
code hygene

When looking at data for PSCO, I noticed that a couple of solar plants in Maryland are being assigned PSCO as their physical BA code: ![image](https://github.com/singularity-energy/open-grid-emissions/assets/45949268/82611958-fdb5-4a08-83aa-765e35c71305) We do not currently...

methodology
data cleaning
regional aggregation

The `eia930.manual_930_adjust()` function adjusts incorrect timestamps in the raw EIA-930 data: https://github.com/singularity-energy/open-grid-emissions/blob/bb0c0329c54b25cfc0e0c550ebf242bb7930f733/src/eia930.py#L368 However, while poking around in this function as part of https://github.com/singularity-energy/open-grid-emissions/pull/300, it became clear that there are some...

data cleaning
code hygene
hourly profiles
consumed emissions
generation data

The OGE pipeline currently can use several methods to identify a plant's primary fuel: based on the fuel consumption, based on net generation, or based on nameplate capacity (see [docs](https://docs.singularity.energy/docs/open-grid-emissions-docs/primary_fuel-assigning-primary-fuels))....

methodology
validation
generation data

Idea from Gailin: I think it would be good to add an automatic diff of the output data, to flag regions and times with large changes and identify the magnitude...

new feature
validation
data outputs

The uncontrolled SO2 and NOx emission factor tables that we use are manually created based on two tables included as part of the EIA's Electric Power Annual. However, in copying...

data inputs
emissions

According to page 16 of the EIA's Electric Power Monthly [Technical Notes](https://www.eia.gov/electricity/monthly/pdf/technotes.pdf), whenever a generator only reports gross generation, they use the following conversion factors to calculate net generation: ![image](https://user-images.githubusercontent.com/45949268/184950232-a2bc503a-e9b8-4013-8491-94c0843ce0db.png)...

methodology
data repair
eia
gross-to-net generation
generation data

Starting in 2020, it appears that the Ormesa geothermal plants (plant 50766 and 54724) started switching from ST prime movers to BT prime movers. However, in 2020, the prime mover...

eia
emissions
generation data

We should set up pre-commit hooks for enforcing formatting and other requirements in the code, especially if we start having more contributors. Catalyst has a template repo available that we...

code hygene

There are several ways that the CHP adjustment (used to calculate `emission_mass_lb_for_electricity` could be improved. ### Assumed values - [ ] When calculating `useful_thermal_output`, `data_cleaning.calculate_electric_allocation_factor()` uses an assumed efficiency factor...

question
methodology
epa
emissions