Greg Miller
Greg Miller
This will make our functions easier to read. https://peps.python.org/pep-0484/
When looking at data for PSCO, I noticed that a couple of solar plants in Maryland are being assigned PSCO as their physical BA code:  We do not currently...
The `eia930.manual_930_adjust()` function adjusts incorrect timestamps in the raw EIA-930 data: https://github.com/singularity-energy/open-grid-emissions/blob/bb0c0329c54b25cfc0e0c550ebf242bb7930f733/src/eia930.py#L368 However, while poking around in this function as part of https://github.com/singularity-energy/open-grid-emissions/pull/300, it became clear that there are some...
The OGE pipeline currently can use several methods to identify a plant's primary fuel: based on the fuel consumption, based on net generation, or based on nameplate capacity (see [docs](https://docs.singularity.energy/docs/open-grid-emissions-docs/primary_fuel-assigning-primary-fuels))....
Idea from Gailin: I think it would be good to add an automatic diff of the output data, to flag regions and times with large changes and identify the magnitude...
The uncontrolled SO2 and NOx emission factor tables that we use are manually created based on two tables included as part of the EIA's Electric Power Annual. However, in copying...
According to page 16 of the EIA's Electric Power Monthly [Technical Notes](https://www.eia.gov/electricity/monthly/pdf/technotes.pdf), whenever a generator only reports gross generation, they use the following conversion factors to calculate net generation: ...
Starting in 2020, it appears that the Ormesa geothermal plants (plant 50766 and 54724) started switching from ST prime movers to BT prime movers. However, in 2020, the prime mover...
We should set up pre-commit hooks for enforcing formatting and other requirements in the code, especially if we start having more contributors. Catalyst has a template repo available that we...
There are several ways that the CHP adjustment (used to calculate `emission_mass_lb_for_electricity` could be improved. ### Assumed values - [ ] When calculating `useful_thermal_output`, `data_cleaning.calculate_electric_allocation_factor()` uses an assumed efficiency factor...