brubeck
brubeck copied to clipboard
Not compliant with statsd spec wrt counters and meters
The spec here -> https://github.com/b/statsd_spec <- indicates that counters are indicated by 'c' and meters by 'm'.
The statsd sampler indicates counters as 'C', meters as 'c', and fails to recognize 'm'.
Not sure what 'C' is in brubeck but it corresponds to what internally is called a counter. The 'c' is internally a meter, and 'm' is not present. I believe it's fairly benign to treat 'c' as a meter and add 'm' to be treated the same way.