AutoStatsQ
AutoStatsQ copied to clipboard
Strange behaviour of AutoStatQ for posthole sensor
Hi Gesa, during some attempts to use AutostatQ to perform quality checks on a small temporary network in Northern Italy, I found strange behaviour in the software that I still have no answer to. The seismic network is composed of several equipment and as the first attempt I selected only the broadband stations. I can complete the step' sequence to the end for most of them but not for one station. This is a posthole station located at -252 m of depth and only for this one, I was not able to complete the restitution step before performing the checks. The config file is the same, stations.pf file is the same, inventory file is the same but only for this station I cannot get the data. I checked the XML file and all the information seems to be ok as well as the waveforms metadata, I also tried several combinations of pf file but the problems remain. Do you have an idea about the problem? Just to give you some more detail in the attachment you find the station.pf, inventory and configuration files that I'm using, the log file for the Restitution step I got and an example of an earthquake recorded by the station. Let me know if you have a suggestion about the problem... Thank you in advance, Simone div05.zip