mqtt-io
mqtt-io copied to clipboard
ina219 i2c_bus_num - unknown field
I have a ina219 sensor on i2c available on bus 10 with address 0x43. I can confirm it works with a default python script.
But with mqtt-io it doesnt.
Code:
root@RD-CLUST00:/srv# python3 -m mqtt_io config.yaml
2023-06-23 14:01:30 mqtt_io.__main__ [ERROR] MqttIo crashed!
Traceback (most recent call last):
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/__main__.py", line 107, in main
mqtt_gpio.run()
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/server.py", line 1242, in run
self._init_sensor_modules()
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/server.py", line 255, in _init_sensor_modules
self.sensor_modules[sens_config["name"]] = _init_module(
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/server.py", line 122, in _init_module
module_config = validate_and_normalise_config(module_config, module_schema)
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/config/__init__.py", line 105, in validate_and_normalise_config
raise ConfigValidationFailed(
mqtt_io.exceptions.ConfigValidationFailed: Config did not validate:
i2c_bus_num:
- unknown field
Traceback (most recent call last):
File "/usr/lib/python3.9/runpy.py", line 197, in _run_module_as_main
return _run_code(code, main_globals, None,
File "/usr/lib/python3.9/runpy.py", line 87, in _run_code
exec(code, run_globals)
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/__main__.py", line 115, in <module>
main()
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/__main__.py", line 107, in main
mqtt_gpio.run()
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/server.py", line 1242, in run
self._init_sensor_modules()
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/server.py", line 255, in _init_sensor_modules
self.sensor_modules[sens_config["name"]] = _init_module(
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/server.py", line 122, in _init_module
module_config = validate_and_normalise_config(module_config, module_schema)
File "/usr/local/lib/python3.9/dist-packages/mqtt_io/config/__init__.py", line 105, in validate_and_normalise_config
raise ConfigValidationFailed(
mqtt_io.exceptions.ConfigValidationFailed: Config did not validate:
i2c_bus_num:
- unknown field
yaml:
mqtt:
host: X
port: x
user: "X"
password: "X"
topic_prefix: pimqttgpio/mydevice
sensor_modules:
# An LM75 sensor attached to the I2C bus
- name: ina219_sensor
module: ina219
i2c_bus_num: 10
chip_addr: 0x43
sensor_inputs:
# The configuration of the specific sensor value to use (LM75 only has temperature)
- name: power
module: ina219_sensor
What did I do wrong?
Your config contains an extra key i2c_bus_num
. You have probably copied it from LM75 config, but it is invalid for ina219
.
Valid configuration for ina219
must match this schema:
https://github.com/flyte/mqtt-io/blob/7367dd1fb34903564f27044f3f02fd8df452c04a/mqtt_io/modules/sensor/ina219.py#L31-L47
Makes sense.. But this way it doesn't allow you to set the i2c bus number.
the Python3 script works now.. but sadly, it still does not read any values. But that's an other issue I guess. I've already changed the script to add "i2c_bus_num" and will make a pull-request.
I added a pull request to include i2c_bus_num. It's in the develop repo now: 2bb2f945ea47ed87f99ab4fc966d2dbbd47fc7c7