Elli Pro: Charging Power Level reported wrong and Charged Values are incorrect
Describe the bug
One of the latest evcc I observed that the values of the "charge Level" is wrongly reported. This leads to a wrong value of charged capacity. I am charging a Skoda Octavia just maximal charging is at 3.6kw and not more.
Steps to reproduce
Every time by charging the car.
Configuration details
# open evcc at http://evcc.local:7070
network:
schema: http
host: evcc.home # .local suffix announces the hostname on MDNS
port: 7070
log: debug
levels:
cache: error
mqtt:
broker: 192.168.0.xxx:1883
topic: evcc
clientid: evcc
user: ....
password: ....
# unique installation id
plant: f2f9266b536181d7afad4f6e4605db48757accf5a6337c9567a31468481ca004
interval: 10s # control cycle interval
meters:
- type: template
template: huawei-dongle-powersensor
id: 1
host: 192.168.0.xxx
port: 502
usage: grid
modbus: tcpip
timeout: 15s
name: grid1
- type: template
template: huawei-dongle-powersensor
id: 1
host: 192.168.0.xxx
port: 502
usage: pv
modbus: tcpip
timeout: 15s
name: pv2
- type: template
template: huawei-dongle-powersensor
id: 1
host: 192.168.0.xxx
port: 502
usage: battery
modbus: tcpip
timeout: 15s
name: battery3
chargers:
- type: template
template: ellipro
ski: xxxx xxxx xxxx xxxx xxxx .....
ip: 192.168.0.xxx
name: wallbox4
loadpoints:
- title: Elli
charger: wallbox4
mode: minpv
site:
title: home
meters:
grid: grid1
pv:
- pv2
battery:
- battery3
vehicles:
type: template
template: skoda
Title: Skoda Octavia
user: xxxxxxxx
password: xxxxxxxx
vin: xxxxxxxx
capacity: 13
name: Octavia
eebus:
certificate:
private: |
-----BEGIN EC PRIVATE KEY-----
-----END EC PRIVATE KEY-----
public: |
-----BEGIN CERTIFICATE-----
-----END CERTIFICATE-----h
Log details
[site ] DEBUG 2024/08/22 12:42:25 battery power: 0W
[site ] DEBUG 2024/08/22 12:42:25 grid meter: -447W
[eebus ] DEBUG 2024/08/22 12:42:26 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2244 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:27 grid currents: [9.71 -5.92 -5.48]A
[eebus ] DEBUG 2024/08/22 12:42:28 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2245 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:30 site power: -447W
[lp-1 ] DEBUG 2024/08/22 12:42:30 !! session: chargeRater.chargedEnergy=9.9 - chargedAtStartup=0.0
[lp-1 ] DEBUG 2024/08/22 12:42:30 charger status: C
[eebus ] DEBUG 2024/08/22 12:42:30 !! OpEV.LoadControlLimits set: {a false false 16}
[lp-1 ] DEBUG 2024/08/22 12:42:30 pv charge current: 16.6A = 16A + 0.648A (-447W @ 3p)
[site ] DEBUG 2024/08/22 12:42:30 ----
[lp-1 ] DEBUG 2024/08/22 12:42:30 charge power: 11040W
[eebus ] DEBUG 2024/08/22 12:42:30 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2246 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:42:32 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2247 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:33 pv power: 5020W
[eebus ] DEBUG 2024/08/22 12:42:34 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2248 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:42:36 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2249 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:37 battery soc: 0%
[site ] DEBUG 2024/08/22 12:42:37 battery power: 0W
[site ] DEBUG 2024/08/22 12:42:37 grid meter: -445W
[eebus ] DEBUG 2024/08/22 12:42:38 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2250 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:42:40 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2251 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:41 grid currents: [9.69 -5.92 -5.5]A
[site ] DEBUG 2024/08/22 12:42:41 site power: -445W
[lp-1 ] DEBUG 2024/08/22 12:42:41 !! session: chargeRater.chargedEnergy=9.9 - chargedAtStartup=0.0
[lp-1 ] DEBUG 2024/08/22 12:42:41 charger status: C
[eebus ] DEBUG 2024/08/22 12:42:41 !! OpEV.LoadControlLimits set: {a false false 16}
[lp-1 ] DEBUG 2024/08/22 12:42:41 pv charge current: 16.6A = 16A + 0.645A (-445W @ 3p)
[site ] DEBUG 2024/08/22 12:42:41 ----
[lp-1 ] DEBUG 2024/08/22 12:42:41 charge power: 11040W
[eebus ] DEBUG 2024/08/22 12:42:42 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2252 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:44 pv power: 5028W
[eebus ] DEBUG 2024/08/22 12:42:44 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2253 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:42:46 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2254 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:47 battery soc: 0%
[site ] DEBUG 2024/08/22 12:42:47 battery power: 0W
[site ] DEBUG 2024/08/22 12:42:48 grid meter: -449W
[eebus ] DEBUG 2024/08/22 12:42:48 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2255 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:42:50 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2256 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:51 grid currents: [9.68 -5.87 -5.49]A
[site ] DEBUG 2024/08/22 12:42:51 site power: -449W
[lp-1 ] DEBUG 2024/08/22 12:42:51 !! session: chargeRater.chargedEnergy=10.0 - chargedAtStartup=0.0
[lp-1 ] DEBUG 2024/08/22 12:42:51 charger status: C
[eebus ] DEBUG 2024/08/22 12:42:51 !! OpEV.LoadControlLimits set: {a false false 16}
[lp-1 ] DEBUG 2024/08/22 12:42:51 pv charge current: 16.7A = 16A + 0.651A (-449W @ 3p)
[site ] DEBUG 2024/08/22 12:42:51 ----
[lp-1 ] DEBUG 2024/08/22 12:42:51 charge power: 11040W
[eebus ] DEBUG 2024/08/22 12:42:52 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2257 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:54 pv power: 5043W
[eebus ] DEBUG 2024/08/22 12:42:54 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2258 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:42:56 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2259 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:58 battery soc: 0%
[site ] DEBUG 2024/08/22 12:42:58 battery power: 0W
[eebus ] DEBUG 2024/08/22 12:42:58 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2260 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:42:59 grid meter: -441W
[eebus ] DEBUG 2024/08/22 12:43:00 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2261 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:43:01 grid currents: [9.72 -5.87 -5.49]A
[eebus ] DEBUG 2024/08/22 12:43:02 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2262 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:43:03 site power: -441W
[lp-1 ] DEBUG 2024/08/22 12:43:03 !! session: chargeRater.chargedEnergy=10.0 - chargedAtStartup=0.0
[lp-1 ] DEBUG 2024/08/22 12:43:03 charger status: C
[eebus ] DEBUG 2024/08/22 12:43:03 !! OpEV.LoadControlLimits set: {a false false 16}
[lp-1 ] DEBUG 2024/08/22 12:43:03 pv charge current: 16.6A = 16A + 0.639A (-441W @ 3p)
[site ] DEBUG 2024/08/22 12:43:03 ----
[lp-1 ] DEBUG 2024/08/22 12:43:03 charge power: 11040W
[site ] DEBUG 2024/08/22 12:43:04 pv power: 5036W
[eebus ] DEBUG 2024/08/22 12:43:04 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2263 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:43:06 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2264 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:43:08 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2265 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:43:10 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2266 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:43:12 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2267 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:43:13 battery soc: 0%
[site ] DEBUG 2024/08/22 12:43:13 battery power: 0W
[site ] DEBUG 2024/08/22 12:43:14 grid meter: -434W
[eebus ] DEBUG 2024/08/22 12:43:14 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2268 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:43:16 grid currents: [9.73 -5.86 -5.49]A
[eebus ] DEBUG 2024/08/22 12:43:16 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2269 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:43:17 site power: -434W
[lp-1 ] DEBUG 2024/08/22 12:43:17 !! session: chargeRater.chargedEnergy=10.0 - chargedAtStartup=0.0
[lp-1 ] DEBUG 2024/08/22 12:43:17 charger status: C
[eebus ] DEBUG 2024/08/22 12:43:17 !! OpEV.LoadControlLimits set: {a false false 16}
[lp-1 ] DEBUG 2024/08/22 12:43:17 pv charge current: 16.6A = 16A + 0.629A (-434W @ 3p)
[site ] DEBUG 2024/08/22 12:43:17 ----
[lp-1 ] DEBUG 2024/08/22 12:43:17 charge power: 11040W
[eebus ] DEBUG 2024/08/22 12:43:18 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2270 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:43:20 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2271 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:43:21 pv power: 5025W
[eebus ] DEBUG 2024/08/22 12:43:22 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2272 DeviceDiagnosisHeartbeatData
[eebus ] DEBUG 2024/08/22 12:43:24 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2273 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:43:25 battery soc: 0%
[site ] DEBUG 2024/08/22 12:43:25 battery power: 0W
[site ] DEBUG 2024/08/22 12:43:26 grid meter: -487W
[eebus ] DEBUG 2024/08/22 12:43:26 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2274 DeviceDiagnosisHeartbeatData
[site ] DEBUG 2024/08/22 12:43:27 grid currents: [9.67 -5.86 -5.65]A
[site ] DEBUG 2024/08/22 12:43:28 site power: -487W
[lp-1 ] DEBUG 2024/08/22 12:43:28 !! session: chargeRater.chargedEnergy=10.1 - chargedAtStartup=0.0
[lp-1 ] DEBUG 2024/08/22 12:43:28 charger status: C
[eebus ] DEBUG 2024/08/22 12:43:28 !! OpEV.LoadControlLimits set: {a false false 16}
[lp-1 ] DEBUG 2024/08/22 12:43:28 pv charge current: 16.7A = 16A + 0.706A (-487W @ 3p)
[site ] DEBUG 2024/08/22 12:43:28 ----
[lp-1 ] DEBUG 2024/08/22 12:43:28 charge power: 11040W
[eebus ] DEBUG 2024/08/22 12:43:28 Send: d:_i:47859_Elli-Wallbox-2149A1UPID notify 2275 DeviceDiagnosisHeartbeatData
What type of operating system are you running?
Linux
Version
0.130.2
please remove personal data from "Configuration details"
vehicles: user: xxx password: xxx vin: xxx
The root cause is the breaking change about the use of the meter data in the elli pro, see #15367
please remove personal data from "Configuration details"
Consider password burned. Change, don't reuse!
And: configure Skoka as phases: 1.
We're discussing re-enabling the Elli Pro meter, stay tuned.
My Elli Pro Wallbox is currently running on EVCC 0.129.0 and is more stable than it has been for a long time. I am aware that you had to laboriously implement many workarounds for the wallbox and that a lot of energy and time was invested in this. My special thanks go to DerAndereAndi! I understand the reasons behind the current breaking change. However, reactivating the Elli Pro meter would be an option that I would welcome, as I cannot simply install an external meter. I could deal with the resulting errors.
We're discussing re-enabling the Elli Pro meter, stay tuned.
any news?
Elli Pro meter support has been re-added in https://github.com/evcc-io/evcc/pull/15778. Nightly can be tested in 30min.