Easee 3p->1p Umschaltung: schaltet gleich wieder auf 3p hoch (#12825 follow up)

Open kai-morich opened this issue 3 months ago • 3 comments

Describe the bug

Zunächst wird auf 1phasig runtergeschaltet

[easee ] TRACE 2024/03/22 10:31:02 POST https://api.easee.com/api/sites/400000/circuits/300000/settings
[easee ] TRACE 2024/03/22 10:31:02 {"dynamicCircuitCurrentP1":16,"dynamicCircuitCurrentP2":0,"dynamicCircuitCurrentP3":0}

Die Easee hat mit der Umschaltung begonnen, in dem sie sich abschaltet und kurz danach wieder 1phasig anschalten würde.

Währenddessen ist evcc der Annahme das genug Überschuss für 3phasig vorhanden ist

[lp-1  ] DEBUG 2024/03/22 10:31:35 available power 4341W > 4140W min 3p threshold

und schaltet wieder hoch

[easee ] TRACE 2024/03/22 10:31:35 POST https://api.easee.com/api/sites/400000/circuits/300000/settings
[easee ] TRACE 2024/03/22 10:31:35 {"dynamicCircuitCurrentP1":16,"dynamicCircuitCurrentP2":16,"dynamicCircuitCurrentP3":16}

was die Easee wegen 'Lastausgleich' erst nach einigen Minuten ausführt.

Im Grafana-Dashboard ist zu sehen, das der Überschuss (grün - gelb) maximal einige 100 Watt ist.

Screenshot 2024-03-22 104222

Der unrealistische Überschuss war schon in https://github.com/evcc-io/evcc/issues/12825#issuecomment-1987221102 aufgefallen, aber zunächst wurde erst etwas anderes gefixt

Steps to reproduce

Um die Situation unabhängig vom Sonnenstand zu erzwingen hatte ich zunächst im Modus 'schnell' mit 3p geladen, dann mit 'Min+PV' auf zunächst 3 * 6A reduziert. Ab hier beginnt das begefügte log / screenshot. Nach dem Phasetimer sollte eigentlich auf 1 * 6A runtergeschaltet werden, da nur <1500 Watt Sonnenertrag vorhanden sind. Stattdessen wird versucht wieder auf 3 Phasen hochzuschalten, was die Easee wegen 'Lastausgleich' erst nach einigem Minuten macht. Das 3phasige Wiedereinschalten ist nicht mehr im log / screenshot enthalten.

Configuration details

network:
  schema: http
  host: localhost
  port: 7070
log: debug
levels:
  easee: trace
sponsortoken: ***
plant: ***

meters:
- name: grid
  type: template
  template: vzlogger
  usage: grid
  host: ***
  port: 2071
  uuid: ***
- name: pv
  type: template
  template: solarlog 
  usage: pv  
  host: ***
  port: 2081

chargers:
- name: wallbox
  type: template
  template: easee
  user: ***
  password: ***
  charger: ABCDEF
  timeout: 30s
  authorize: true

loadpoints:
- title: Zuhause
  charger: wallbox
  mode: pv
  phases: 0

vehicles:
- name: id.4
  title: ID.4
  type: template
  template: vw
  user: ***
  password: ***

influx:
  url: ***
  token: ***
  org: home
  database: evcc
  
site:
  title: Zuhause
  meters:
    grid: grid
    pv: pv

Log details

[main  ] INFO 2024/03/21 22:51:57 evcc 0.124.10
...
[site  ] DEBUG 2024/03/22 10:30:02 pv power: 1461W
[site  ] DEBUG 2024/03/22 10:30:02 grid meter: 3897W
[site  ] DEBUG 2024/03/22 10:30:02 site power: 3897W
[lp-1  ] DEBUG 2024/03/22 10:30:02 charge currents: [6.04 6.03 5.97]A
[lp-1  ] DEBUG 2024/03/22 10:30:02 detected active phases: 3p
[lp-1  ] DEBUG 2024/03/22 10:30:02 charge total import: 3448.002kWh
[lp-1  ] DEBUG 2024/03/22 10:30:02 charger status: C
[lp-1  ] DEBUG 2024/03/22 10:30:02 vehicle soc: 60%
[lp-1  ] DEBUG 2024/03/22 10:30:02 vehicle soc limit: 90%
[lp-1  ] DEBUG 2024/03/22 10:30:02 vehicle range: 252km
[lp-1  ] DEBUG 2024/03/22 10:30:02 available power 297W < 4140W min 3p threshold
[lp-1  ] DEBUG 2024/03/22 10:30:02 phase scale1p in 1m0s
[lp-1  ] DEBUG 2024/03/22 10:30:02 pv charge current: 0.352A = 6A + -5.65A (3897W @ 3p)
[site  ] DEBUG 2024/03/22 10:30:02 ----
[lp-1  ] DEBUG 2024/03/22 10:30:02 charge power: 4194W
[easee ] TRACE 2024/03/22 10:30:13 ProductUpdate ABCDEF: (2024-03-22 09:30:12 +0000 UTC) TEMP_INPUT_T2 30
[easee ] TRACE 2024/03/22 10:30:13 ProductUpdate ABCDEF: (2024-03-22 09:30:12 +0000 UTC) TEMP_INPUT_T4 29
[easee ] TRACE 2024/03/22 10:30:13 ProductUpdate ABCDEF: (2024-03-22 09:30:12 +0000 UTC) TEMP_OUTPUT_L1 29
[easee ] TRACE 2024/03/22 10:30:13 ProductUpdate ABCDEF: (2024-03-22 09:30:12 +0000 UTC) TEMP_INPUT_T3 29
[easee ] TRACE 2024/03/22 10:30:13 ProductUpdate ABCDEF: (2024-03-22 09:30:12 +0000 UTC) TEMP_INPUT_T5 29
[easee ] TRACE 2024/03/22 10:30:13 ProductUpdate ABCDEF: (2024-03-22 09:30:12 +0000 UTC) TEMP_OUTPUT_L3 28
[easee ] TRACE 2024/03/22 10:30:13 ProductUpdate ABCDEF: (2024-03-22 09:30:12 +0000 UTC) TEMP_OUTPUT_N 29
[easee ] TRACE 2024/03/22 10:30:13 ProductUpdate ABCDEF: (2024-03-22 09:30:12 +0000 UTC) TEMP_OUTPUT_L2 28
[site  ] DEBUG 2024/03/22 10:30:32 pv power: 1458W
[site  ] DEBUG 2024/03/22 10:30:32 grid meter: 3884W
[site  ] DEBUG 2024/03/22 10:30:32 site power: 3884W
[lp-1  ] DEBUG 2024/03/22 10:30:32 charge currents: [6.04 6.03 5.97]A
[lp-1  ] DEBUG 2024/03/22 10:30:32 detected active phases: 3p
[lp-1  ] DEBUG 2024/03/22 10:30:32 charge total import: 3448.002kWh
[lp-1  ] DEBUG 2024/03/22 10:30:32 charger status: C
[lp-1  ] DEBUG 2024/03/22 10:30:32 vehicle soc: 60%
[lp-1  ] DEBUG 2024/03/22 10:30:32 vehicle soc limit: 90%
[lp-1  ] DEBUG 2024/03/22 10:30:32 vehicle range: 252km
[lp-1  ] DEBUG 2024/03/22 10:30:32 available power 310W < 4140W min 3p threshold
[lp-1  ] DEBUG 2024/03/22 10:30:32 phase scale1p in 30s
[lp-1  ] DEBUG 2024/03/22 10:30:32 pv charge current: 0.371A = 6A + -5.63A (3884W @ 3p)
[site  ] DEBUG 2024/03/22 10:30:32 ----
[lp-1  ] DEBUG 2024/03/22 10:30:32 charge power: 4194W
[easee ] TRACE 2024/03/22 10:31:00 POST https://api.easee.com/api/chargers/ABCDEF/commands/poll_lifetimeenergy
[easee ] TRACE 2024/03/22 10:31:00 {"device":"ABCDEF","commandId":2,"ticks":638466966602091290}
[easee ] TRACE 2024/03/22 10:31:00 CommandResponse ABCDEF: {SerialNumber:ABCDEF ID:2 Timestamp:2024-03-22 09:31:00.209129 +0000 UTC DeliveredAt:2024-03-22 09:30:59.813 +0000 UTC WasAccepted:true ResultCode:0 Comment: Ticks:638466966602091290}
[easee ] TRACE 2024/03/22 10:31:01 ProductUpdate ABCDEF: (2024-03-22 09:30:59 +0000 UTC) LIFETIME_ENERGY 3448.002009444459
[site  ] DEBUG 2024/03/22 10:31:02 pv power: 1459W
[site  ] DEBUG 2024/03/22 10:31:02 grid meter: 3922W
[site  ] DEBUG 2024/03/22 10:31:02 site power: 3922W
[lp-1  ] DEBUG 2024/03/22 10:31:02 charge currents: [6.04 6.03 5.97]A
[lp-1  ] DEBUG 2024/03/22 10:31:02 detected active phases: 3p
[lp-1  ] DEBUG 2024/03/22 10:31:02 charge total import: 3448.002kWh
[lp-1  ] DEBUG 2024/03/22 10:31:02 charger status: C
[lp-1  ] DEBUG 2024/03/22 10:31:02 vehicle soc: 60%
[lp-1  ] DEBUG 2024/03/22 10:31:02 vehicle soc limit: 90%
[lp-1  ] DEBUG 2024/03/22 10:31:02 vehicle range: 252km
[lp-1  ] DEBUG 2024/03/22 10:31:02 available power 272W < 4140W min 3p threshold
[lp-1  ] DEBUG 2024/03/22 10:31:02 phase scale1p in 0s
[easee ] TRACE 2024/03/22 10:31:02 GET https://api.easee.com/api/sites/400000/circuits/300000/settings
[easee ] TRACE 2024/03/22 10:31:02 {"allowOfflineMaxCircuitCurrent":false,"equalizerId":null,"masterChargerId":"ABCDEF","useDynamicMaster":false,"dynamicCircuitCurrentP1":16.0,"dynamicCircuitCurrentP2":16.0,"dynamicCircuitCurrentP3":16.0,"enableIdleCurrent":true,"maxCircuitCurrentP1":16.0,"maxCircuitCurrentP2":16.0,"maxCircuitCurrentP3":16.0,"offlineMaxCircuitCurrentP1":16,"offlineMaxCircuitCurrentP2":16,"offlineMaxCircuitCurrentP3":16}
[easee ] TRACE 2024/03/22 10:31:02 POST https://api.easee.com/api/sites/400000/circuits/300000/settings
[easee ] TRACE 2024/03/22 10:31:02 {"dynamicCircuitCurrentP1":16,"dynamicCircuitCurrentP2":0,"dynamicCircuitCurrentP3":0}
[lp-1  ] DEBUG 2024/03/22 10:31:02 switched phases: 1p
[lp-1  ] DEBUG 2024/03/22 10:31:02 phase timer inactive
[lp-1  ] DEBUG 2024/03/22 10:31:02 pv charge current: 0A = 6A + -17.1A (3922W @ 1p)
[site  ] DEBUG 2024/03/22 10:31:02 ----
[lp-1  ] DEBUG 2024/03/22 10:31:02 charge power: 4194W
[easee ] TRACE 2024/03/22 10:31:03 ProductUpdate ABCDEF: (2024-03-22 09:31:02 +0000 UTC) DYNAMIC_CIRCUIT_CURRENT_P3 0
[easee ] TRACE 2024/03/22 10:31:03 ProductUpdate ABCDEF: (2024-03-22 09:31:02 +0000 UTC) DYNAMIC_CIRCUIT_CURRENT_P1 16
[easee ] TRACE 2024/03/22 10:31:03 ProductUpdate ABCDEF: (2024-03-22 09:31:02 +0000 UTC) DYNAMIC_CIRCUIT_CURRENT_P2 0
[easee ] TRACE 2024/03/22 10:31:03 ProductUpdate ABCDEF: (2024-03-22 09:31:02 +0000 UTC) CIRCUIT_TOTAL_ALLOCATED_PHASE_CONDUCTOR_CURRENT_L3 0
[easee ] TRACE 2024/03/22 10:31:03 ProductUpdate ABCDEF: (2024-03-22 09:31:02 +0000 UTC) CIRCUIT_TOTAL_ALLOCATED_PHASE_CONDUCTOR_CURRENT_L2 0
[easee ] TRACE 2024/03/22 10:31:03 CommandResponse ABCDEF: {SerialNumber:ABCDEF ID:22 Timestamp:2024-03-22 09:31:02.473227 +0000 UTC DeliveredAt:2024-03-22 09:31:02.103 +0000 UTC WasAccepted:true ResultCode:0 Comment: Ticks:638466966624732270}
[easee ] TRACE 2024/03/22 10:31:04 ProductUpdate ABCDEF: (2024-03-22 09:31:02 +0000 UTC) REASON_FOR_NO_CURRENT 27
[easee ] TRACE 2024/03/22 10:31:04 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) REASON_FOR_NO_CURRENT 6
[easee ] TRACE 2024/03/22 10:31:04 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) IN_CURRENT_T4 3.9709999561309814
[easee ] TRACE 2024/03/22 10:31:04 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) IN_CURRENT_T5 3.4579999446868896
[easee ] TRACE 2024/03/22 10:31:04 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) IN_CURRENT_T3 3.6640000343322754
[easee ] TRACE 2024/03/22 10:31:04 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) CHARGER_OP_MODE 2
[easee ] TRACE 2024/03/22 10:31:04 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) OUTPUT_CURRENT 0
[easee ] TRACE 2024/03/22 10:31:04 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) PILOT_MODE B
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) CIRCUIT_TOTAL_ALLOCATED_PHASE_CONDUCTOR_CURRENT_L1 0
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) CIRCUIT_TOTAL_PHASE_CONDUCTOR_CURRENT_L2 3.9709999561309814
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:04 +0000 UTC) OUT_VOLT_PIN1_4 0.8920000195503235
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) CIRCUIT_TOTAL_PHASE_CONDUCTOR_CURRENT_L1 3.6640000343322754
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:03 +0000 UTC) CIRCUIT_TOTAL_PHASE_CONDUCTOR_CURRENT_L3 3.4579999446868896
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:04 +0000 UTC) OUT_VOLT_PIN1_3 1.8880000114440918
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:04 +0000 UTC) LEDMODE 21
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:04 +0000 UTC) OUT_VOLT_PIN1_5 2.00600004196167
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:04 +0000 UTC) OUTPUT_PHASE 0
[easee ] TRACE 2024/03/22 10:31:05 ProductUpdate ABCDEF: (2024-03-22 09:31:04 +0000 UTC) TOTAL_POWER 0
[easee ] TRACE 2024/03/22 10:31:10 ProductUpdate ABCDEF: (2024-03-22 09:31:08 +0000 UTC) CIRCUIT_TOTAL_PHASE_CONDUCTOR_CURRENT_L1 0.00800000037997961
[easee ] TRACE 2024/03/22 10:31:10 ProductUpdate ABCDEF: (2024-03-22 09:31:08 +0000 UTC) CIRCUIT_TOTAL_PHASE_CONDUCTOR_CURRENT_L3 0.00800000037997961
[easee ] TRACE 2024/03/22 10:31:10 ProductUpdate ABCDEF: (2024-03-22 09:31:08 +0000 UTC) CIRCUIT_TOTAL_PHASE_CONDUCTOR_CURRENT_L2 0.004000000189989805
[easee ] TRACE 2024/03/22 10:31:10 ProductUpdate ABCDEF: (2024-03-22 09:31:09 +0000 UTC) IN_CURRENT_T5 0.00800000037997961
[easee ] TRACE 2024/03/22 10:31:10 ProductUpdate ABCDEF: (2024-03-22 09:31:09 +0000 UTC) IN_CURRENT_T4 0.004000000189989805
[easee ] TRACE 2024/03/22 10:31:10 ProductUpdate ABCDEF: (2024-03-22 09:31:09 +0000 UTC) IN_CURRENT_T3 0.008999999612569809
[easee ] TRACE 2024/03/22 10:31:15 ProductUpdate ABCDEF: (2024-03-22 09:31:13 +0000 UTC) TEMP_INPUT_T3 29
[easee ] TRACE 2024/03/22 10:31:15 ProductUpdate ABCDEF: (2024-03-22 09:31:13 +0000 UTC) TEMP_OUTPUT_N 29
[easee ] TRACE 2024/03/22 10:31:15 ProductUpdate ABCDEF: (2024-03-22 09:31:13 +0000 UTC) TEMP_INPUT_T2 30
[easee ] TRACE 2024/03/22 10:31:15 ProductUpdate ABCDEF: (2024-03-22 09:31:13 +0000 UTC) TEMP_INPUT_T4 29
[easee ] TRACE 2024/03/22 10:31:15 ProductUpdate ABCDEF: (2024-03-22 09:31:13 +0000 UTC) TEMP_OUTPUT_L3 28
[easee ] TRACE 2024/03/22 10:31:15 ProductUpdate ABCDEF: (2024-03-22 09:31:13 +0000 UTC) TEMP_INPUT_T5 29
[easee ] TRACE 2024/03/22 10:31:15 ProductUpdate ABCDEF: (2024-03-22 09:31:13 +0000 UTC) TEMP_OUTPUT_L1 29
[easee ] TRACE 2024/03/22 10:31:15 ProductUpdate ABCDEF: (2024-03-22 09:31:13 +0000 UTC) TEMP_OUTPUT_L2 28
[site  ] DEBUG 2024/03/22 10:31:32 pv power: 1459W
[site  ] DEBUG 2024/03/22 10:31:32 grid meter: -147W
[site  ] DEBUG 2024/03/22 10:31:32 site power: -147W
[lp-1  ] DEBUG 2024/03/22 10:31:32 charge currents: [0.009 0.004 0.008]A
[lp-1  ] DEBUG 2024/03/22 10:31:32 charge total import: 3448.002kWh
[lp-1  ] DEBUG 2024/03/22 10:31:32 charger status: B
[lp-1  ] INFO 2024/03/22 10:31:32 stop charging <-
[lp-1  ] DEBUG 2024/03/22 10:31:32 wake-up timer: start
[lp-1  ] DEBUG 2024/03/22 10:31:32 charge total import: 3448.002kWh
[lp-1  ] DEBUG 2024/03/22 10:31:35 vehicle soc: 60%
[lp-1  ] DEBUG 2024/03/22 10:31:35 vehicle soc limit: 90%
[lp-1  ] DEBUG 2024/03/22 10:31:35 vehicle range: 253km
[lp-1  ] DEBUG 2024/03/22 10:31:35 available power 4341W > 4140W min 3p threshold
[lp-1  ] DEBUG 2024/03/22 10:31:35 phase scale3p in 0s
[easee ] TRACE 2024/03/22 10:31:35 GET https://api.easee.com/api/sites/400000/circuits/300000/settings
[easee ] TRACE 2024/03/22 10:31:35 {"allowOfflineMaxCircuitCurrent":false,"equalizerId":null,"masterChargerId":"ABCDEF","useDynamicMaster":false,"dynamicCircuitCurrentP1":16.0,"dynamicCircuitCurrentP2":0.0,"dynamicCircuitCurrentP3":0.0,"enableIdleCurrent":true,"maxCircuitCurrentP1":16.0,"maxCircuitCurrentP2":16.0,"maxCircuitCurrentP3":16.0,"offlineMaxCircuitCurrentP1":16,"offlineMaxCircuitCurrentP2":16,"offlineMaxCircuitCurrentP3":16}
[easee ] TRACE 2024/03/22 10:31:35 POST https://api.easee.com/api/sites/400000/circuits/300000/settings
[easee ] TRACE 2024/03/22 10:31:35 {"dynamicCircuitCurrentP1":16,"dynamicCircuitCurrentP2":16,"dynamicCircuitCurrentP3":16}
[lp-1  ] DEBUG 2024/03/22 10:31:35 switched phases: 3p
[lp-1  ] DEBUG 2024/03/22 10:31:35 phase timer inactive
[lp-1  ] DEBUG 2024/03/22 10:31:35 pv charge current: 0.213A = 0A + 0.213A (-147W @ 3p)
[site  ] DEBUG 2024/03/22 10:31:35 ----
[lp-1  ] DEBUG 2024/03/22 10:31:35 charge power: 0W
[easee ] TRACE 2024/03/22 10:31:36 CommandResponse ABCDEF: {SerialNumber:ABCDEF ID:22 Timestamp:2024-03-22 09:31:35.517405 +0000 UTC DeliveredAt:2024-03-22 09:31:35.043 +0000 UTC WasAccepted:true ResultCode:0 Comment: Ticks:638466966955174050}
[easee ] TRACE 2024/03/22 10:31:36 ProductUpdate ABCDEF: (2024-03-22 09:31:35 +0000 UTC) DYNAMIC_CIRCUIT_CURRENT_P3 16
[easee ] TRACE 2024/03/22 10:31:36 ProductUpdate ABCDEF: (2024-03-22 09:31:35 +0000 UTC) DYNAMIC_CIRCUIT_CURRENT_P1 16
[easee ] TRACE 2024/03/22 10:31:36 ProductUpdate ABCDEF: (2024-03-22 09:31:35 +0000 UTC) DYNAMIC_CIRCUIT_CURRENT_P2 16
[site  ] DEBUG 2024/03/22 10:32:05 pv power: 1457W
[site  ] DEBUG 2024/03/22 10:32:05 grid meter: -138W
[site  ] DEBUG 2024/03/22 10:32:05 site power: -138W
[lp-1  ] DEBUG 2024/03/22 10:32:05 charge currents: [0.009 0.004 0.008]A
[lp-1  ] DEBUG 2024/03/22 10:32:05 charge total import: 3448.002kWh
[lp-1  ] DEBUG 2024/03/22 10:32:05 charger status: B
[lp-1  ] DEBUG 2024/03/22 10:32:05 pv charge current: 0.2A = 0A + 0.2A (-138W @ 3p)
[site  ] DEBUG 2024/03/22 10:32:05 ----
[lp-1  ] DEBUG 2024/03/22 10:32:05 charge power: 0W
[site  ] DEBUG 2024/03/22 10:32:35 pv power: 1458W
[site  ] DEBUG 2024/03/22 10:32:35 grid meter: -432W
[site  ] DEBUG 2024/03/22 10:32:35 site power: -432W
[lp-1  ] DEBUG 2024/03/22 10:32:35 charge currents: [0.009 0.004 0.008]A
[lp-1  ] DEBUG 2024/03/22 10:32:35 charge total import: 3448.002kWh
[lp-1  ] DEBUG 2024/03/22 10:32:35 charger status: B
[lp-1  ] DEBUG 2024/03/22 10:32:35 pv charge current: 0.626A = 0A + 0.626A (-432W @ 3p)
[lp-1  ] DEBUG 2024/03/22 10:32:35 wake-up vehicle, attempts left: 4
[site  ] DEBUG 2024/03/22 10:32:35 ----
[lp-1  ] DEBUG 2024/03/22 10:32:35 charge power: 0W

What type of operating system are you running?

Linux

Version

0.124.10

kai-morich avatar Mar 22 '24 10:03 kai-morich

available power 4341W > 4140W min 3p threshold

interessant. Wo kommt das her? Und warum geht es ohne Timer wieder hoch?

/cc @GrimmiMeloni @MarkusGH

andig avatar Mar 22 '24 17:03 andig

gibt es noch weitere traces die ich einschalten sollte?

kai-morich avatar Mar 22 '24 17:03 kai-morich

Wenn man den ganzen Lärm von der Easee mal beiseite lässt fällt auf, daß in jedem Intervall 30s nichts passiert zwischen

[lp-1  ] DEBUG 2024/03/22 10:31:35 charge power: 0W
[...]
[site  ] DEBUG 2024/03/22 10:32:05 pv power: 1457W

Spannend ist wo wir die Zeit verlieren. Vielleicht in Site.updateMeters() ? @kai-morich kannst Du für Deine meters mal Trace logging einschalten? Vielleicht sehen wir dann wo genau die Zeit verloren geht.

GrimmiMeloni avatar Mar 23 '24 17:03 GrimmiMeloni

Neuer Fall in evcc23.log aufgezeichnet mit log: trace und Fehler irgendwo in diesem Bereich:

[easee ] TRACE 2024/03/24 15:22:51 {"dynamicCircuitCurrentP1":16,"dynamicCircuitCurrentP2":0,"dynamicCircuitCurrentP3":0}
...   
[lp-1  ] DEBUG 2024/03/24 15:23:25 available power 4596W > 4140W min 3p threshold
...
[easee ] TRACE 2024/03/24 15:23:25 {"dynamicCircuitCurrentP1":16,"dynamicCircuitCurrentP2":16,"dynamicCircuitCurrentP3":16}

Mir ist aufgefallen; das mein selbst gebauter solarlog/modbus kompatibler PV-Datenlogger nur je einen Request beantwortet und dann den Socket schließt. 15 Sekunden wird der zweite Request wiederholt. Kann dies die Berechnung durcheinander bringen?

Screenshot 2024-03-24 160036

kai-morich avatar Mar 24 '24 15:03 kai-morich

@andig da sollte mal jemand mit Modbus Kenntnis draufschauen. Die Easee hat hier keinen Einfluss.

GrimmiMeloni avatar Mar 24 '24 16:03 GrimmiMeloni

Hab mein modbus server umgebaut. Mal abwarten ob dies etwas ändert.

kai-morich avatar Mar 24 '24 16:03 kai-morich

Seit https://github.com/evcc-io/evcc/issues/13090#issuecomment-2015522550 sehe ich keine neue Erkenntnis und v.a. auch keine Antwort auf die Frage. Da kann ich nix beitragen.

andig avatar Mar 24 '24 16:03 andig