kalibr icon indicating copy to clipboard operation
kalibr copied to clipboard

Always get T=(0,0,0)

Open gongyue666 opened this issue 3 years ago • 1 comments

Hi all, nowadays I use kalibr to calibrate realsense L515 and a extend IMU. I do steps follow the tutorial , everything seems ok , but the final result get a T = (0,0,0). image my camera and imu fix like this. image final result like this. have I do something wrong to get this?

gongyue666 avatar Nov 19 '21 12:11 gongyue666

Hi,

The time shift is too large. So are the accelerometer and gyroscope errors. This makes me think that there is a problem in the data acquisition process. My advice: plot your rosbag using rqt and check whether data from camera and IMU are synched. Furthermore, plot your camera and IMU coordinate frames and make sure that the rotation matrices R_ic and R_ci make sense!

Regards, Mohammad

mhyoosefian avatar Nov 24 '21 14:11 mhyoosefian