flownet icon indicating copy to clipboard operation
flownet copied to clipboard

Unexpected behaviour for very simple box-type models

Open olwijn opened this issue 4 years ago • 0 comments

box_model9.tar.gz It was observed that for a symmetric 2-layer box model with a 5-spot well development and the multiple perforation option (and a water-oil contact between the 2 layers), the connections are not symmetric. The files to reproduce this behaviour are attached to this issue (note: ocw_depth in yml file is incorrect, should be 2570 instead of 2590). image image

It is not entirely clear at this moment to what extent this behaviour, as well as other characteristics of Delaunay triangulation (for example, without the central 5th well, there would be only 1 diagonal), will affect the performance of network architectures of real-field FlowNet models.

olwijn avatar Jun 10 '21 10:06 olwijn