Add aux heater limits

Open proddy opened this issue 3 years ago • 1 comments

Discussed in https://github.com/emsesp/EMS-ESP32/discussions/644

Originally posted by Cali1205 September 25, 2022 While working on optimizing the power consuption of my heat pump together with my PV system I thought it is a good idea to be able to control the power to the aux heater. My idea is to use the limit setting of the aux heater. PXL_20220918_155339209 - Kopie

I think it would be very helpful to have these setting available.

The register seems to be 0x492.

Description Offset
aux heater limit with compressor active 2
aux heater limit heating 3
aux heater limit hot water 4

And the values are:

Reg Value Value
0 0kW
1 2kW
2 3kW
3 4kW
4 6kW
5 9kW

proddy avatar Sep 25 '22 11:09 proddy

I've added this to PR #650, needs to be checked by a user with this heatpump.

MichaelDvP avatar Sep 28 '22 15:09 MichaelDvP

thanks. closing for now.