Calculate dhw standby loss

Open andrekuehne opened this issue 9 months ago • 1 comments

This introduces the option to fit an exponential decay to the DHW temperature vs. time curve as seen in the power graph. Functionality is implemented similar to the "Estimate system volume..." checkbox. A heat loss coefficient in W/K is shown, the fitted temperature is overlaid on the power graph as visual indicator of fit quality. Correctness was checked by uploading an artificial dataset with 5W/K decay of a 300l tank:

image

andrekuehne avatar Apr 07 '25 14:04 andrekuehne

Checkbox to enable/disable DHW added here as well

andrekuehne avatar Apr 07 '25 15:04 andrekuehne

Very nice, thanks @andrekuehne !!