Vivek Gopalakrishnan
Vivek Gopalakrishnan
Looks good! > I analyzed the cxr.nii.gz file and found that the space for cxr.nii is (0.703125, 0.703125, 2.5). Why is it set to 2.0 in your code instead of...
For rendering X-rays based on a real physical imaging system, see DiffPose: https://github.com/eigenvivek/DiffPose
Hi @linquanxu sorry for the late reply 1. Is there a reason you can't render a 300 x 300 DRR and use the same delx as the real X-ray? But...
Hi @Nick19111996 cool images! The first thing that jumps out is the circular crop on your fluoroscopy image... I've never tested DiffDRR with an image like that, so perhaps the...
Hi @Nick19111996 closing for now, feel free to reopen if you're still facing any issues!
Hi @Hooray-Lee , sorry for the slow reply. ### Issue 1 That result is surprising. What's the affine matrix for your volume? Also what orientation are you using in `read`?...
Hi @poretga99, it's always a fun time transforming from one person's affine geometry to another's :) DiffDRR is able to support all the geometry geometry you have (including the principal...
Hi @poretga99 sorry for the slow reply on this. If you still want to find the intrinsic/extrinsic parameters, feel free to send me an email and we can try to...
Could we simply change the default function if the pytorch version is `>=2.3` (perhaps while also raising a warning for the user)? E.g., we could add something like this to...