dRICH: update envelope dimensions and positioning
Is your feature request related to a problem? Please describe. Latest envelope changes from Alessandro: https://indico.bnl.gov/event/19746/
rmax2 = 180, down from 185
zmin = 200, up from 195; this is a shift in +z by 5 cm
zmax = 322, up from 320 (after shift of zmin to 200); extra 2 cm on the back end
bore diameters: 20.0 to 35.2
considering a vertical FMS split; would require 90 degree rotation of the sectors
Describe the solution you'd like
- [ ] cross check these numbers with Alessandro's slides
- note the 2cm gain on the back end is from communication during the meeting, and may not be on the slides
- [ ] change the envelope
- [ ] check the optics
- [ ] re-tune the optics
I will implement it.
Are you sure these 20 and 35.2 are not the diameters but radii?
Are you sure these 20 and 35.2 are not the diameters but radii?
good catch, they are likely diameters; I fixed the description above.
I have wrote Marco for a final confirmation. Anyway, the working branch is dRICH_envelope_07052023
We need to re-tune the optics quite a lot!
We need to re-tune the optics quite a lot!
Business as usual. Every time the envelope is changed the optics need to be checked and re-tuned, even if it's "just a small change".
Anyway, the working branch is
dRICH_envelope_07052023
Can you make a draft PR and link it to this issue?