ADM-CID 407 & 408

Open amitfin opened this issue 2 years ago • 2 comments

Pima Force 144 alarm uses "ADM-CID" format.

407 Code

The alarm system has a mobile app PIMAlink 3.0 which can be used to arm and disarm the alarm system. When using the mobile app (and not the keypad), the alarm is sending event 407: "Remote arm/disarm": 2023-09-21 01:59:23.136 DEBUG (MainThread) [pysiaalarm.base_server] Incoming line: 7449003F"ADM-CID"0078R1L0#AAAA[#00AAAA|3407 01 001]_01:59:16,09-21-2023

408 Code

When using the keypad's "arm away" button, the alarm sends event 408: "Quick arm" 2023-10-04 13:26:45.185 DEBUG (MainThread) [pysiaalarm.base_server] Incoming line: 9B2F0041"ADM-CID"1285R1L0#AAAAAA[#AAAAAA|3408 01 000]_13:26:16,10-04-2023

image

(ADM-CID code can be found here).

Adding new mappings for events 407 & 408.

The updated mapping file was tested with our alarm system and it's working as expected. The state of the alarm entity is getting updated correctly.

amitfin avatar Sep 20 '23 23:09 amitfin

Not sure why tests were failing (Tox passes locally), but according to the log the failed test case seems unrelated to this change (not even ADM-CID): testSIA.test_parse_and_check[encrypted-altered_key-siadcs]

amitfin avatar Oct 02 '23 04:10 amitfin

Regarding the errors in the tests:

This is the output of tox when running locally in the dev-environment (docker):

py38: SKIP (0.35 seconds)
py39: OK (46.80=setup[14.09]+cmd[32.71] seconds)
py310: OK (85.34=setup[52.08]+cmd[33.27] seconds)
py311: SKIP (0.02 seconds)
mypy: OK (36.20=setup[35.30]+cmd[0.91] seconds)
congratulations :) (168.93 seconds)

(devcontainer.json was changed locally with "VARIANT": "3.10", so py310 will be executed. This is the verion which failed in the workflow).

amitfin avatar Oct 04 '23 14:10 amitfin