test error between paper and the code
Hi, I have same questions about the result error of this paper. I am looking forward for your replying!!!
-
Can you tell how you get the test error? Because the dataset of eval error part is the same with the test part. In my opinion, you choose the best validation result of the training process as the test error.
-
Why the best error result of ablation part in Table1 is
8.48mm
onICVL
dataset, which is not the same with the result in Table1 (6.73mm
).
8.48 is the result trained with 2w dataset, I think you should read the paper carefully, but not question so much.