dsmr-reader
dsmr-reader copied to clipboard
Sweden/Luxembourg: Support decimals for phase_power_current_l*
Feature
These are integers in the DSMR-protocol, but not in Sweden not Luxembourg:
phase_power_current_l1phase_power_current_l2phase_power_current_l3
Consider converting it to decimals, even though it will hit a lot and also cause a lot of trouble in keep it compatible with existing data, so it may not happen.
Reported in #1394 / #1533.
1-0:31.7.0(011.7*A)
1-0:51.7.0(000.3*A)
1-0:71.7.0(009.2*A)
/FLU5\253769484_A
1-0:31.7.0(001.06*A)
1-0:51.7.0(002.07*A)
1-0:71.7.0(001.47*A)
/KAM5
0-0:1.0.0(220120135735W)
1-0:1.8.0(00000184.554*kWh)
1-0:2.8.0(00000000.000*kWh)
1-0:3.8.0(00000001.082*kVArh)
1-0:4.8.0(00000091.984*kVArh)
1-0:1.7.0(0004.795*kW)
1-0:2.7.0(0000.000*kW)
1-0:3.7.0(0000.000*kVAr)
1-0:4.7.0(0000.079*kVAr)
1-0:21.7.0(0002.619*kW)
1-0:41.7.0(0000.073*kW)
1-0:61.7.0(0002.103*kW)
1-0:22.7.0(0000.000*kW)
1-0:42.7.0(0000.000*kW)
1-0:62.7.0(0000.000*kW)
1-0:23.7.0(0000.000*kVAr)
1-0:43.7.0(0000.000*kVAr)
1-0:63.7.0(0000.000*kVAr)
1-0:24.7.0(0000.010*kVAr)
1-0:44.7.0(0000.028*kVAr)
1-0:64.7.0(0000.041*kVAr)
1-0:32.7.0(228.2*V)
1-0:52.7.0(230.2*V)
1-0:72.7.0(228.6*V)
1-0:31.7.0(011.7*A)
1-0:51.7.0(000.3*A)
1-0:71.7.0(009.2*A)
!232C