This is of limited help but i did do a blog about how you can use the options to find different versions of SWMM5. Unfortunately, most consecutive SWMM5 releases have...

I was confused and used the wrong smiley!

There are a few other changes such as changes to the LID section and Weir sections (more data) but those only work if the user uses the new feature. If...

Update and improve documentation - not to pick on you but I have been seeing that comment for 40+ years.

here is the comment in the SWMM3 manual in 1981 - so having too much output as always been an issue Statistics Block -- Output from continuous simulation can be...

There are three parameters in a storage function Area = A + B^C though you can get by just using A.

@michaeltryby it would be good if SWMM acknowledged the user defined unit flag in the Raingage property so that a user could use USA unit rainfall in an SI unit...

If you want a value per node you should convert the default manholes or junctions to storage nodes and use a constant surface area for the storages.

I 2nd @bemcdonnell suggestion about a log file. So many users ignore the top of the rpt file. A separate log file might be easier for them to pay attention...