This is what I get with v12 for RDII in your test model EPA STORM WATER MANAGEMENT MODEL - VERSION 5.1 (Build 5.1.012)- QA/QC -------------------------------------------------------------- Test SWMM 5.1.013 RDII/RUNOFF related...

@martensgd actually the proposed solution does not work, I get the same answers in native v13 and modified v13. The issue is the rainfall, somehow, the RDII is causing the...

I am still looking at this but if you turn off RDII in v13 you get the same runoff in v12 and v13. If you duplicate your time series and...

Shouldn't that be checked in the GUI or PCSWMM? I think it is checked in SWMM5 - no it is not checked - you can have right and left bank...

The code Lew Rossman has only sends a line to the report file if the value of the control setting has changed. It might be worthwhile to show when a...

It seems as if Fmax is used for both Horton and Modified Horton in infil.c - is it being exported for the Modified Horton option? What does the inp file...

Yes, thanks @MikeGregory-Canada for finding this bug from Canada.

Those 32.2 values have something to do with SWMM4 and SWMM3 - here is how it is defined in SWMM4 GRVT = 32.2 IF(METRIC.EQ.2) GRVT = 9.806 IF(AMEN.EQ.0.0.AND.METRIC.EQ.1) AMEN =...

Interesting, I can duplicate or triplicate your issue in many other models. This is strange as I have or thought I had many models with no known map coordinates. I...

Or course this is a Delphi reading problem with the RPT file. In the actual report file, it does seem like the weir depth is in the right place. I...