SolarEdge-Exporter icon indicating copy to clipboard operation
SolarEdge-Exporter copied to clipboard

No metrics for SE5000H

Open thiagofigueiro opened this issue 4 years ago • 10 comments

Hi! thanks for sharing this project. I tried using it with my SolarEdge inverter but no meter values came back.

Here's the output with debug enabled:

12:38 $ ./SolarEdge-Exporter
12:38PM INF Starting SolarEdge-Exporter
12:38PM INF Configured Inverter Address: 192.168.1.6
12:38PM INF Configured Inverter Port: 1502
12:38PM INF Configured Listen Address:
12:38PM INF Configured Listen Port: 2112
12:38PM INF Inverter Model: SE5000H-AU000BWU4
12:38PM INF Inverter Serial: <redacted>
12:38PM INF Inverter Version: 0004.0011.0030
12:38PM INF Meter Manufacturer:
12:38PM INF Meter Model:
12:38PM INF Meter Serial:
12:38PM INF Meter Version:
12:38PM INF Meter Option:
12:38PM DBG Meter AC Current: 0.000000
12:38PM DBG Meter VoltageLN: 0.000000
12:38PM DBG Meter PF: 0
12:38PM DBG Meter Freq: 0.000000
12:38PM DBG Meter AC Power: 0.000000
12:38PM DBG Meter M_AC_VA: 0.000000
12:38PM DBG Meter M_Exported: 0.000000
12:38PM DBG Meter M_Imported: 0.000000
12:38PM DBG -------------------------------------------

Using https://github.com/nmakel/solaredge_modbus, I get these values:

[ { 'fields': { 'c_deviceaddress': 1.0,
                'c_sunspec_did': 101.0,
                'current': 20.17,
                'current_dc': 11.314,
                'energy_total': 1194932.0,
                'frequency': 50.024,
                'p1_current': 20.17,
                'p1_voltage': 248.1,
                'p1n_voltage': 0.0,
                'p2_current': 0.0,
                'p2_voltage': 0.0,
                'p2n_voltage': 0.0,
                'p3_current': 0.0,
                'p3_voltage': 0.0,
                'p3n_voltage': 0.0,
                'power_ac': 5004.0,
                'power_apparent': 5009.0,
                'power_dc': 5080.0,
                'power_factor': 99.89,
                'power_reactive': 226.48,
                'status': 5.0,
                'temperature': 57.69,
                'vendor_status': 0.0,
                'voltage_dc': 449.0},
    'measurement': 'inverter',
    'tags': { 'c_deviceaddress': 1,
              'c_manufacturer': 'SolarEdge',
              'c_model': 'SE5000H-AU000BWU4',
              'c_serialnumber': '<redacted>',
              'c_sunspec_did': 101,
              'c_version': '0004.0011.0030'},
    'time': '2021-01-09T01:40:22Z'}]

In the readme you mention this was "Tested with SE5000 w. CPU version 3.2221.0". If this is comparable to the c_version above, then I'm running 4.11.30, which is a major version above.

I'd be happy to provide some debugging data to try and get this working with the new version. Please let me know if I can go anything on my side. Thank you.

thiagofigueiro avatar Jan 09 '21 01:01 thiagofigueiro