cryptk
cryptk
Awesome, I'll fix the version reporting next time I push an update
There should be a PH sensor already and ORP should be shown as an attribute on that PH sensor. I already plan to split the ORP data out to it's...
There is not attachment to that comment. I don't know if attachments work with email replies, you might need to attach it in the GitHub UI itself
@umchemist your issue is because your chlorinator is a CO2 type, which wasn't mentioned in the documentation that I have. I'll work on getting that supported. @krucka this issue is...
@krucka can you downgrade the integration to get back to a working state, pull diagnostic info from the integration and then open a new issue with that diag info? Actually,...
@krucka try the new version (0.7.12) and if you still have issues, then downgrade, pull diagnostics and open a NEW issue with those diagnostics attached.
This issue was originally for getting the PH/ORP sensor values available in the integration. When doing a simulation run with the diagnostics provided, those are now available: Going to close...
I have no idea what a Hayward EyesPool is... can you give me some information about it?
Is it controlled by the OmniLogic? It sounds like it has it's own app, which would mean control of that device is outside of the scope of this integration.
That would require it's own integration then. This integration is scoped to the OmniLogic only.