Feature Request: Allow for specification of electronic temperature

Open heindelj opened this issue 1 year ago • 2 comments

For some systems, especially containing highly-charged ions, xtb struggles to converge the SCF with the default electronic temperature of 300K. If there were a command-line switch to specify a higher electronic temperature, this would enable ensemble searches in non-covalent mode with higher-chareged cations and could likely be useful in other contexts as well.

heindelj avatar Oct 07 '23 22:10 heindelj

Hi, you can already do that via input files (the same as specifying constraints using --cinp). It needs to go in the $scc block with temp=

pprcht avatar Oct 12 '23 09:10 pprcht

This issue had no activity for 6 months. It will be closed in 1 week unless there is some new activity.