IRremoteESP8266
IRremoteESP8266 copied to clipboard
Panasonic CS-E12QKEW
Hello,
you can add the "Panasonic CS-E12QKEW" to the compatibility List, its working fine with following Settings
Tasmota Log (in older tasmota versions "Model":"DKE" shows Model":3):
14:10:29.104 MQT: stat/Klimaanlage_Buero/RESULT = {"IRHVAC":{"Vendor":"PANASONIC_AC","Model":"DKE","Command":"Control","Mode":"Auto","Power":"Off","Celsius":"On","Temp":22,"FanSpeed":"Min","SwingV":"High","SwingH":"Middle","Quiet":"Off","Turbo":"On","Econo":"Off","Light":"Off","Filter":"Off","Clean":"Off","Beep":"Off","Sleep":-1,"Clock":910,"iFeel":"Off","SensorTemp":"n/a"}}
Homeasssitant Settings (i think "hvac_model: 3" ist only the important thing):
#Büro
- platform: tasmota_irhvac
name: "Klimaanlage Buero"
command_topic: "cmnd/Klimaanlage_Buero/irhvac"
# Pick one of the following:
# State is updated when the tasmota device receives an IR signal (includes own transmission and original remote)
# useful when a normal remote is in use alongside the tasmota device, may be less reliable than the second option.
#state_topic: "tele/Klimaanlage_Buero/RESULT"
# State is updated when the tasmota device completes IR transmission, should be pretty reliable.
#state_topic: "stat/your_tasmota_device/RESULT"
# Uncomment if your 'available topic' of Tasmota IR device are different (if device in HA is disabled)
#availability_topic: "tele/your_tasmota_device/LWT"
temperature_sensor: sensor.wohnzimmer_temperatursensor_snzb_02_temperature
humidity_sensor: sensor.wohnzimmer_temperatursensor_snzb_02_humidity #optional - default None
#power_sensor: binaly_sensor.kitchen_ac_power #optional - default None
vendor: "PANASONIC_AC"
min_temp: 16 #optional - default 16 int value
max_temp: 30 #optional - default 32 int value
target_temp: 26 #optional - default 26 int value
initial_operation_mode: "off" # optional - default "off" string value (one of the "supported_modes")
#away_temp: 24 #optional - default 24 int value (preset_modes)
precision: 1 #optional - default 1 int or float value. Can be set to 1, 0.5 or 0.1
supported_modes:
- "auto"
- "heat"
- "cool"
- "dry"
- "fan_only" # Use "fan_only" even if Tasmota shows "Mode":"Fan"
- "off" #Turns the AC off - Should be in quotes
# Some devices have "auto" and "fan_only" switched. If the following two lines are uncommented, "auto" and "fan" shoud be commented out
#- "auto_fan_only" #if remote shows fan but tasmota says auto
#- "fan_only_auto" #if remote shows auto but tasmota says fan
supported_fan_speeds:
# Some devices say max,but it is high, and auto which is max. If you uncomment the following two, you have to comment high and max
# - "auto_max" #woud become max
# - "max_high" #would become high
#- "on"
#- "off"
- "auto"
- "min"
- "low"
- "medium"
- "high"
- "max"
supported_swing_list:
- "off"
- "vertical" #up to down
- "horizontal" # Left to right
#- "both"
default_quiet_mode: "Off" #Quiet und Turbo sind in der Firmware vertauscht | optional - default "Off" string value
default_turbo_mode: "On" #Quiet und Turbo sind in der Firmware vertauscht | optional - default "Off" string value
default_econo_mode: "Off" #optional - default "Off" string value
hvac_model: "3" #optional - default "1" string value
celsius_mode: "On" #optional - default "On" string value
default_light_mode: "Off" #optional - default "Off" string value
default_filter_mode: "Off" #optional - default "Off" string value
default_clean_mode: "Off" #optional - default "Off" string value
default_beep_mode: "Off" #optional - default "Off" string value
default_sleep_mode: "-1" #optional - default "-1" string value
default_swingv: "high" #optional - default "" string value
default_swingh: "middle" #optional - default "" string value
keep_mode_when_off: True #optional - default False boolean value : Must be True for MITSUBISHI_AC, ECOCLIM, etc.
Thanks for the report, do you also have a model of the remote? I would like to make it clear that there is a difference between "works with" and "is using" the later is preferred but requires actually dumps of what the original remote sends to confirm.
Sure here is the original remote code:
11:59:29.472 MQT: tele/Klimaanlage_Buero/RESULT = {"IrReceived":{"Protocol":"PANASONIC_AC","Bits":216,"Data":"0x0220E004000000060220E00400092C805106000EE0000081000081","Repeat":0,"IRHVAC":{"Vendor":"PANASONIC_AC","Model":"NKE","Command":"Control","Mode":"Auto","Power":"On","Celsius":"On","Temp":22,"FanSpeed":"Medium","SwingV":"Highest","SwingH":"Middle","Quiet":"Off","Turbo":"Off","Econo":"Off","Light":"Off","Filter":"Off","Clean":"Off","Beep":"Off","Sleep":-1,"iFeel":"Off","SensorTemp":"n/a"}}}
Information: With your project Model 0 is working, but no swing and Econo is possible, all other features are working With your project Model 3 is only Econo no working, all other features are working (RollingKey maybe?)
"Econo On" original remote code: 12:03:57.755 MQT: tele/Klimaanlage_Buero/RESULT = {"IrReceived":{"Protocol":"UNKNOWN","Bits":486,"Hash":"0x9F9E8B11","Repeat":0}}
Remote Picture:
Edit: turbo and quiet are reversed
"Econo On" original remote code: 12:03:57.755 MQT: tele/Klimaanlage_Buero/RESULT = {"IrReceived":{"Protocol":"UNKNOWN","Bits":486,"Hash":"0x9F9E8B11","Repeat":0}}
FYI: This bit doesn't help us at all. See: https://github.com/crankyoldgit/IRremoteESP8266/wiki/Frequently-Asked-Questions#my-remotes-signal-is-being-reported-as-an-unknown-code-what-does-that-mean-how-do-i-send-an-unknown-code