NextGen-IFC icon indicating copy to clipboard operation
NextGen-IFC copied to clipboard

Use only SI units in exhange

Open pasi-paasiala opened this issue 4 years ago • 2 comments

Description of the proposal:

Use only metric units in IFC. For example, have all length values as meters.

What do we win:

  • Reading of IFC is simplified. You don't need to convert from exotic units to your internal units.
  • Precision concerns can be thought of in one go: We can advice, for example, how to model very large projects (infrastructure)

What do we loose

  • Nothing, the user of the reading application can use whatever display units they want

Schema impact:

  • Schema is simplified

Instance model impact:

  • Simpler files

Backwards compatible:

  • no

Automatic migration possible: ?

Additional implications:

Note that not all points need to be satisfied! Backwards compatibility and file size are not concerns.

pasi-paasiala avatar Mar 13 '20 06:03 pasi-paasiala

In the Vilnius ISG meeting we had a discussion about this and it was proposed that we could have a "preferred" display unit added. I don't mind.

pasi-paasiala avatar Mar 13 '20 06:03 pasi-paasiala

@pasi-paasiala does this mean that the proposal has been accepted? (i.e. only SI units in exchange, with a new way to assign a preferred display unit)

If so, I really, really, really +1 this.

Moult avatar Mar 23 '20 03:03 Moult