MixSIAR icon indicating copy to clipboard operation
MixSIAR copied to clipboard

Normalization when combining SI and FA

Open OMBengtsson opened this issue 3 years ago • 1 comments

Hi! I have been looking into the possibility to use MixSIAR for a combined dataset with both stable isotopes and fatty acids as tracers, as done in the study by O'Donovan et al. 2018. The following quote is from their paper and addresses the problem of combining continuous (SI) and compositional (FA) data: "Importantly, the two biomarkers cannot be merged and used in the Bayesian mixing model without a transformation to put them on the same scale of measurement. Accordingly, the SI–FA dataset was transformed by subtracting the mean and dividing by the standard deviation (Dethier et al. 2013), making the two biomarkers quantitatively comparable during modeling." My question is then - doesn't the run_model function already normalize the tracer data before modelling - making any prior normalization redundant? Best regards /Olof

OMBengtsson avatar Aug 10 '21 14:08 OMBengtsson

Yes, you are correct, run_model normalizes the tracer data so they do not need to be normalized beforehand. For details, see lines 211-254 and comment on 30-38.