HX711 icon indicating copy to clipboard operation
HX711 copied to clipboard

hx711 module design fault fix

Open konosubakonoakua opened this issue 4 years ago • 7 comments

Solution: Use A wire to connect E- and GND FH7R58EJ7UR7KPT LARGE I read the datasheet of HX711, and found a design fault of the hx711 moudule in the market. Snipaste_2020-02-28_18-26-25 In the picture above, we can see that the pin-5 is AGND, The picture below shows the recommended application in it's datasheet. Snipaste_2020-02-28_18-27-12 It should be connected to GND, but the module dosen't do that. Snipaste_2020-02-28_18-24-10 But we can still use the module, because the current can flow back via SCK pin, when it's low level. However, it's not stable.

konosubakonoakua avatar Feb 28 '20 10:02 konosubakonoakua