Hi, @PengNi I tried the Deepsignal for 6mA detection and all the position is matched with the 5mC modification on the reference sequence. I don't know what happened about my command. Looking forward to your reply.

deepsignal call_mods --motifs GATC --input_path ./barcode01/deepsignal_feature.tsv --is_gpu yes --model_path ~/software/deepsignal/model.GATC.R9_2D.tem.puc19.bn17.sn360/bn_17.sn_360.epoch_5.ckpt --result_file ./barcode01/deepsignal_prob_A.tsv

Bin-Ma avatar Jun 24 '22 15:06 Bin-Ma

Hi @Bin-Ma , in your step deepsignal extract to generate deepsignal_feature.tsv, the --motifs should be set as --motifs GATC.

Best, Peng

PengNi avatar Jun 25 '22 01:06 PengNi

Hi @PengNi ,

I'm also trying to detect 6mA and 5mC in bacterial sample but only find the model model.GATC.R9_2D.tem.puc19.bn17.sn360/bn_17.sn_360.epoch_5.ckpt in the google drive that are supposed to using on version <0.16. For Deepsignal2, there's only one human CG motif. Does that mean users has to train their model by themselves in such cases? Also for different motif patterns do we all have to train a separate model for each motif?

Thanks, Wen

wenluo711 avatar Sep 26 '22 20:09 wenluo711

@wenluo711 , if you want to detect 6mA and 5mC in bacterial samples, I suggest using Remora/mCaller/nanodisco. Right now deepsignal/deepsignal2 only performs well in 5mCpG detection.

Best, Peng