ATC_MiThermometer
ATC_MiThermometer copied to clipboard
TelinkFlasher web app - send settings to custom firmware not working
Hi All,
At the beginning I would like to thank @atc1441 for his great job with providing flashing tool and custom firmware support. Thank you!
I followed instructions and flashed the latest custom firmware to my LYWSD03MMC device. Everything went good. Then I flashed stock firmware again. I would like to change some default options in custom firmware and I wanted to use that "Send settings to custom firmware" for that purpose but when I hit any button or use text field and hit "Send" button I got in the log messags like "Error on sending setting AF", "Error on sending setting B0", etc. Below screenshot of my log. I am not very familiar with C programming and compiling stuff so web UI allowing to update values in custom firmware is a huge convenience for me but unfortunately it does not work for me.
I tested the latest versions of Chrome/Edge browsers and on both found similar issue. My question is what I am doing wrong? And how to make it to work for me?
Additionaly I would like to ask how to properly add humiditiy offset when I want to add negative number? For offset +10 it is FB+0A, right? For offset -10 it is FB+?? (I don't know as simple conversion of -10 gives me FFFF FFFF FFFF FFF6 result).
Can anyone explain how I should convert int8 to hex when it comes to negative numbers, please?
Thanks in advance for any tips and tricks regarding web flashing tool.
EDIT1: OK. I know where I made a mistake when sending settings to custom firmware. This section works fine when custom firware is already installed on the device so I was able to disable battery info and change advertising type to "Mi Like". I thought that after changing advertising type to "Mi Like" I will be able to use my sensor with Xiaomi Home app but when there is an issue there. Sensor is visible fo Xiaomi Home app but I can't connect it...it fails on verification step. What should I do to use sensor with flashed custom firmware with original Xiaomi Home app?
EDIT2: I think that app MijiaTemp will solve my issue. I can use it on my phone with sensors flashed with custom firmware. Nevertheless I would like to know if it is true that Xiaomi Home app won't work with custom firmware and that it is not possible to overrdie, please?
So at the moment I have two questions.
- How to correctly add negative humidity or temp offset? I don't know how to convert int8 to hex to FB+"XX" format.
- Are there any plans to make custom firmware to work with Xiaomi Home app? Custom firmware gives a possibility to personalize sensors and add offsets which is great.
Cheers!
Hi @KlosiakMK, for the offsets, they are hexadecimal values, being:
positive values from 01(+0.1) to 7F(+12.7), negative values from 80(-12.7) to FF (-0.1) and the value 0 is represented by 00.
Sample commands for adjusting the temp offset, being FA the command and the last 2 digits the offset: FA01 : +0.1 FA02: +0.2 FAFF: -0.1 FA80: -12.7 FA7F: +12.7
Cheers!
Hi @KlosiakMK, for the offsets, they are hexadecimal values, being:
positive values from 01(+0.1) to 7F(+12.7), negative values from 80(-12.7) to FF (-0.1) and the value 0 is represented by 00.
Sample commands for adjusting the temp offset, being FA the command and the last 2 digits the offset: FA01 : +0.1 FA02: +0.2 FAFF: -0.1 FA80: -12.7 FA7F: +12.7
Cheers!
Hi, sure that FA80 is -12,7 ? I think it must be FA81 or is there an mistake in my table? Please check!
FF -0,1 FE -0,2 FD -0,3 FC -0,4 FB -0,5 FA -0,6 F9 -0,7 F8 -0,8 F7 -0,9 F6 -1,0 F5 -1,1 F4 -1,2 F3 -1,3 F2 -1,4 F1 -1,5 F0 -1,6 EF -1,7 EE -1,8 ED -1,9 EC -2,0 EB -2,1 EA -2,2 E9 -2,3 E8 -2,4 E7 -2,5 E6 -2,6 E5 -2,7 E4 -2,8 E3 -2,9 E2 -3,0 E1 -3,1 E0 -3,2 DF -3,3 DE -3,4 DD -3,5 DC -3,6 DB -3,7 DA -3,8 D9 -3,9 D8 -4,0 D7 -4,1 D6 -4,2 D5 -4,3 D4 -4,4 D3 -4,5 D2 -4,6 D1 -4,7 D0 -4,8 CF -4,9 CE -5,0 CD -5,1 CC -5,2 CB -5,3 CA -5,4 C9 -5,5 C8 -5,6 C7 -5,7 C6 -5,8 C5 -5,9 C4 -6,0 C3 -6,1 C2 -6,2 C1 -6,3 C0 -6,4 BF -6,5 BE -6,6 BD -6,7 BC -6,8 BB -6,9 BA -7,0 B9 -7,1 B8 -7,2 B7 -7,3 B6 -7,4 B5 -7,5 B4 -7,6 B3 -7,7 B2 -7,8 B1 -7,9 B0 -8,0 AF -8,1 AE -8,2 AD -8,3 AC -8,4 AB -8,5 AA -8,6 A9 -8,7 A8 -8,8 A7 -8,9 A6 -9,0 A5 -9,1 A4 -9,2 A3 -9,3 A2 -9,4 A1 -9,5 A0 -9,6 9F -9,7 9E -9,8 9D -9,9 9C -10,0 9B -10,1 9A -10,2 99 -10,3 98 -10,4 97 -10,5 96 -10,6 95 -10,7 94 -10,8 93 -10,9 92 -11,0 91 -11,1 90 -11,2 8F -11,3 8E -11,4 8D -11,5 8C -11,6 8B -11,7 8A -11,8 89 -11,9 88 -12,0 87 -12,1 86 -12,2 85 -12,3 84 -12,4 83 -12,5 82 -12,6 81 -12,7
01 0,1 02 0,2 03 0,3 04 0,4 05 0,5 06 0,6 07 0,7 08 0,8 09 0,9 0A 1,0 0B 1,1 0C 1,2 0D 1,3 0E 1,4 0F 1,5 10 1,6 11 1,7 12 1,8 13 1,9 14 2,0 15 2,1 16 2,2 17 2,3 18 2,4 19 2,5 1A 2,6 1B 2,7 1C 2,8 1D 2,9 1E 3,0 1F 3,1 20 3,2 21 3,3 22 3,4 23 3,5 24 3,6 25 3,7 26 3,8 27 3,9 28 4,0 29 4,1 2A 4,2 2B 4,3 2C 4,4 2D 4,5 2E 4,6 2F 4,7 30 4,8 31 4,9 32 5,0 33 5,1 34 5,2 35 5,3 36 5,4 37 5,5 38 5,6 39 5,7 3A 5,8 3B 5,9 3C 6,0 3D 6,1 3E 6,2 3F 6,3 40 6,4 41 6,5 42 6,6 43 6,7 44 6,8 45 6,9 46 7,0 47 7,1 48 7,2 49 7,3 4A 7,4 4B 7,5 4C 7,6 4D 7,7 4E 7,8 4F 7,9 50 8,0 51 8,1 52 8,2 53 8,3 54 8,4 55 8,5 56 8,6 57 8,7 58 8,8 59 8,9 5A 9,0 5B 9,1 5C 9,2 5D 9,3 5E 9,4 5F 9,5 60 9,6 61 9,7 62 9,8 63 9,9 64 10,0 65 10,1 66 10,2 67 10,3 68 10,4 69 10,5 6A 10,6 6B 10,7 6C 10,8 6D 10,9 6E 11,0 6F 11,1 70 11,2 71 11,3 72 11,4 73 11,5 74 11,6 75 11,7 76 11,8 77 11,9 78 12,0 79 12,1 7A 12,2 7B 12,3 7C 12,4 7D 12,5 7E 12,6 7F 12,7
Hi @brain-work @fraagol @KlosiakMK @scy , for offset the humidity command is FB following the value you provide? So, if my sensor shows 50% and I want to be 55%, I have to enter this offset value: FB32? Please help
EDIT: I managed to offste humidity value:
- Using this link https://codebeautify.org/decimal-hex-converter I type the value I want it: 10%
- Result an value "A"
- Using TelinkFlasher App I set the value FBA, send and than save
- that`s it
I found useful this site: https://www.simonv.fr/TypesConvert/?integers
- select decimal radio button
- enter your decimal offset with sign
- took HEX value from SINT8 (without 0x of course)
- Put value right after FA or FB.
f. e.
I had
33%
humidity on sensor. the right value is27%
I entered-6
and got0xFA
so i tookFA
and my offset command isFBFA
don't forget to press Save current settings in flash or send DF command