ArduinoAI
ArduinoAI copied to clipboard
[AE-13] CO2 and IAQ values in Dashboard sketch always 0
Describe the problem
The values for the gas sensor and air quality are not displayed on the Nicla Sense ME dashboard and are always zero.
To reproduce
I am following this tutorial on the docs website: https://docs.arduino.cc/tutorials/nicla-sense-me/web-ble-dashboard
- Open IDE 2.0.4
- Update libraries to latest version (if requested)
- Load the
NiclaSenseME.ino
sketch - The following message is displayed in the
Output
window
Sketch uses 313028 bytes (59%) of program storage space. Maximum is 527616 bytes.
Global variables use 39600 bytes (61%) of dynamic memory, leaving 24688 bytes for local variables. Maximum is 64288 bytes.
"C:\Users\user\AppData\Local\Arduino15\packages\arduino\tools\openocd\0.11.0-arduino2/bin/openocd.exe" -d2 -s "C:\Users\user\AppData\Local\Arduino15\packages\arduino\tools\openocd\0.11.0-arduino2/share/openocd/scripts/" -f interface/cmsis-dap.cfg -c "transport select swd; adapter speed 1000" -f target/nrf52.cfg -c "telnet_port disabled; init; reset init; halt; adapter speed 10000; program {C:\Users\user\AppData\Local\Temp\arduino\sketches\5B5C76D81A5136F18ABEB99A48521561/NiclaSenseME.ino.elf}; reset run; shutdown"
Open On-Chip Debugger 0.11.0+dev-gab95bac57-dirty (2021-05-11-10:45)
Licensed under GNU GPL v2
For bug reports, read
http://openocd.org/doc/doxygen/bugs.html
debug_level: 2
adapter speed: 1000 kHz
Info : CMSIS-DAP: SWD Supported
Info : CMSIS-DAP: FW Version = v1.0
Info : CMSIS-DAP: Serial# = 401D6526
Info : CMSIS-DAP: Interface Initialised (SWD)
Info : SWCLK/TCK = 1 SWDIO/TMS = 1 TDI = 0 TDO = 0 nTRST = 0 nRESET = 1
Info : CMSIS-DAP: Interface ready
Info : clock speed 1000 kHz
Info : SWD DPIDR 0x2ba01477
Info : nrf52.cpu: hardware has 6 breakpoints, 4 watchpoints
Info : starting gdb server for nrf52.cpu on 3333
Info : Listening on port 3333 for gdb connections
target halted due to debug-request, current mode: Thread
xPSR: 0x01000000 pc: 0x00006dc4 msp: 0x20010000
target halted due to debug-request, current mode: Thread
xPSR: 0x01000000 pc: 0x00006dc4 msp: 0x20010000
** Programming Started **
Info : nRF52832-CIAA(build code: E0) 512kB Flash, 64kB RAM
Info : Padding image section 0 at 0x0005b854 with 4 bytes
Warn : Adding extra erase range, 0x0005c6d0 .. 0x0005cfff
** Programming Finished **
shutdown command invoked
- Open the Nicla Sense ME Dashboard with Chrome then pair with the Nicla BLE Sense ME
- The stream for the Indoor Air Quality and CO2 value is constantly zero.
Expected behavior
The value for the Indoor Air Quality and CO2 is non-zero
Arduino IDE version
2.0.4
Operating system
Windows 10
Troubleshooting
Step 1
I uploaded the Standalone.ino sketch, included as part of the Arduino_BHY2 library located in the arduino/nicla-sense-me-fw repo.
In the Serial Monitor, I can see that the value for temperature and gas is non zero. Therefore, I infer that this is not a physical issue with the board, but a possible Bluetooth or software issue.
Step 2
In the NiclaSenseME.ino sketch, I modified the code to print the values of airQuality
and co2
to the Serial Monitor.
I get a bunch of zeros in the Serial Monitor.
This could relate to parsing the data.
As a result of troubleshooting, made an issue here https://github.com/arduino/nicla-sense-me-fw/issues/82
Might be resolved by
- https://github.com/arduino/nicla-sense-me-fw/pull/85
The pressure in the dashboard is too high. 1009 kPa is about 10 times the pressure at sea level (101 kPa).