Enhanced-3DTV icon indicating copy to clipboard operation
Enhanced-3DTV copied to clipboard

Fail to reproduce the results of Washington DC Mall in Compress Sensing task

Open Zeqiang-Lai opened this issue 3 years ago • 5 comments

testdata: x_dc.mat

sampling ratio is 0.2

parameters are set by default:

Rk           = 7;
weight       = [0.015,0.015,0.015];

log of last two iteration

**********************iter: 96 ***********************
stopFormulaVal: 1.1146e-03 
stopFormulaVal2: 1.5997e+01 
beta value is: 0.309133, 0.309133, 0.408828, 4.088284
The clean image: mp = 25.112513, sm = 0.606298, er =1140.122523.
The full image: mp = 25.815700, sm = 0.556139, er =1076.321365.

**********************iter: 97 ***********************
stopFormulaVal: 0.0000e+00 
stopFormulaVal2: 1.5997e+01 
 !!!stopped by termination rule!!! 

Zeqiang-Lai avatar Feb 19 '21 07:02 Zeqiang-Lai