hass-xiaomi-miot icon indicating copy to clipboard operation
hass-xiaomi-miot copied to clipboard

Unable to change temperature unit to Fahrenheit

Open neebski opened this issue 2 years ago • 3 comments

I have two cgllc.airm.cgdn1 and after a recent update they are only reporting in Celsius. I am unable to change the reporting to Fahrenheit. In the mihome app they are reporting in F, only via HA are they reporting C. In the device settings I see there is a unit selection between F, C, K but selecting anything other then C produces no change.

Any suggestions?

neebski avatar Apr 28 '22 22:04 neebski

I have the same issue.

msm8811 avatar May 17 '22 01:05 msm8811

@msm8811

I ended up using unit converter in NodeRed and just made a new entity for fahrenheit. Work around for the time being.

neebski avatar May 17 '22 02:05 neebski

Fixed in https://github.com/al-one/hass-xiaomi-miot/commit/d5f9dd0b3321bb7ba2a7e50dfc6ce2356b55e59b, please upgrade to master branch.