Results not correct

Open gianfrancoquartaruolo opened this issue 2 years ago • 1 comments

I need an help. When I load the TR maps I don’t find a correlation with results summarised in the table.

moreover, TR15 and TR30 differ a lot.

Is there a way to set up the software to have realistic results?

gianfrancoquartaruolo avatar Nov 24 '22 17:11 gianfrancoquartaruolo

RT15 and RT30 can different depending on the room configuration but also if the echogram is too short to calculate the RT with accuracy (not enough dynamic): https://i-simpa-wiki.readthedocs.io/fr/latest/room_acoustics_parameters.html#reverberation RT maps are calculate using surface receivers (2D small plane surface, while for punctual receiver it is calculated using the energy in a spherical volume; it may explain some difference between the two calculation, but it should on the same order.

Could you give some us graphical results? Please use the Discussion tab instead : https://github.com/Universite-Gustave-Eiffel/I-Simpa/discussions

Picaut avatar Nov 25 '22 10:11 Picaut