print_area_bed_mesh icon indicating copy to clipboard operation
print_area_bed_mesh copied to clipboard

Invalid Pattern for some prints

Open bjoern79de opened this issue 2 years ago • 2 comments

For some prints I get the following error message:

bed_mesh: invalid probe_count option when using bicubic interpolation. Combination of 3 points on one axis with more than 6 on another is not permitted. Configured Probe Count: 7, 3

Any hint for globally working base settings for the mesh?

bjoern79de avatar Mar 06 '22 18:03 bjoern79de

...today I had the same problem..hmm - looking at the bed_mesh.py of Klipper I added this block to the if blocks at around line 90 of the script:

                {% if probe_count_x<=3 and probe_count_y>6 %}
                    {% set probe_count_y = 6 %}
                {% endif %}
                {% if probe_count_y<=3 and probe_count_x>6 %}
                    {% set probe_count_x = 6 %}
                {% endif %}```

RURon avatar Jun 01 '22 06:06 RURon

And you solved it?

chopdi avatar Jun 17 '22 15:06 chopdi