Carrier checksum is not calculated correctly in some cases

Open ToniA opened this issue 11 years ago • 1 comments

Certain temperature/fan speed combinations do not produce the same checksum as the real Carrier remote. And of course the heatpump ignores all commands with invalid checksums. Generally fan speeds AUTO, FAN3 and FAN4 seem to work.

ToniA avatar Dec 29 '13 09:12 ToniA

I do not know this case. By decoding the remote control Hisense, the checksum was incorrect in some cases. I finally discovered that it was not a normal sum, it was he the xor of all bytes.

Sorry for my English ;)