Charge transfer energy does not agree between two versions of code
Hi @zhi-wang ,
I noted that my dynamic9 jobs failed with ele-lambda
being 0 with the code of Feb 9. Error message is Induced dipole not converged
.
I compared a previous version (Jan 13), this one ran dynamic and finished.
I ran analyze9
on two versions and I can see the Charge Transfer energy is different by 10 kcal/mol so I am thinking that the new code did not scale down CT energy.
Could you help us solve the issue? For your test, here are the files I used: https://biomol.bme.utexas.edu/~liuchw/Tinker9_DMS/
@roseane-reis Would you add some test cases for these situations? Thanks!