Ultimaker2Marlin icon indicating copy to clipboard operation
Ultimaker2Marlin copied to clipboard

Tinker V16.07 print temperature wrong

Open nicolinux opened this issue 8 years ago • 4 comments

With the latest rc (Tinker V16.07) I've noticed that when I start a print and regardless of the filament profile I select, the temperature is always set to 195°. I have to manually set it to the correct temperature via the tune menu. I have performed a factory reset but the problem still persists.

Tested on an Ultimaker 2 Extended with UltiGcode.

nicolinux avatar Aug 08 '16 10:08 nicolinux

Huh - no more Octoprint? Fascinating... :smile: - where does this value come from? 195° is the default temperature for PLA and 0.25mm nozzle... I assume that there goes something wrong with the additional temperature settings for the different nozzle sizes.

Two short questions:

  • Are your customized material profiles still there? Can you try to export and re-import them?
  • Does your gcode contain comments for the nozzle size at the beginning (from newer Cura versions)?

TinkerGnome avatar Aug 14 '16 21:08 TinkerGnome

Sure, I still use OctoPrint - just not with the UM2 Extended yet.

I didn't create new material profiles - this was just the printer after a firmware reset. I then did customize the default PLA profile and set the temp above 200° but apparently it was not saved. I've sliced with the old Cura 15.x. I'll try the new Cura too then.

nicolinux avatar Aug 15 '16 07:08 nicolinux

Ok, that means:

  • the print starts with the temperature that is stored in the current material profile (so this part is working correct?)
  • but the temperature in the material profile was different from what you expected (probably not stored and lost after a restart? - or all was resetted to the default values?)

Or did i understood something wrong now...?

TinkerGnome avatar Aug 16 '16 12:08 TinkerGnome

Hi, the temperature has been resolve in the new firmware? I download this one V16.07 and has the same problem. picture. I just download the new firmware and have the same problem. The target is 190 and i get a 210 degree. You can see the issue i have in here link in ultimaker community

killerkaos avatar Apr 20 '17 04:04 killerkaos