sofar 8.8ktl-x does not work after updating to 1.5
After updating to 1.5, all entities are unavailable. Downgrade solves the problem.
Create sofar_ktl_x_g3.yaml file in /config/config/custom_components/solarman/inverter_definitions folder with content as below
# SOFAR Solar 8.8KTLX-G3
requests:
- start: 0x0400
end: 0x042B
mb_functioncode: 0x03
- start: 0x0482
end: 0x04A5
mb_functioncode: 0x03
- start: 0x0582
end: 0x0589
mb_functioncode: 0x03
- start: 0x0682
end: 0x068B
mb_functioncode: 0x03
parameters:
- group: Solar
items:
- name: 'PV Generation today
class: 'energy'
state_class: 'total'
uom: 'kWh'
scale: 0.01
rule: 1
registers: [0x0685, 0x0684]
icon: 'mdi:solar-power'
- name: 'PV Generation total'
class: 'energy'
state_class: 'total_increasing'
uom: 'kWh'
scale: 0.1
rule: 3
registers: [0x0687, 0x0686]
icon: 'mdi:solar-power'
- name: 'PV1 Power'
class: 'power'
state_class: 'measurement'
uom: 'W'
scale: 10
rule: 1
registers: [0x0586]
icon: 'mdi:lightning-bolt'
- name: 'PV2 Power'
class: 'power'
state_class: 'measurement'
uom: 'W'
scale: 10
rule: 1
registers: [0x0589]
icon: 'mdi:lightning-bolt'
- name: 'PV1 Voltage''
class: 'voltage'
state_class: 'measurement'
uom: 'V'
scale: 0.1
rule: 1
registers: [0x0584]
icon: 'mdi:sine-wave'
- name: 'PV2 Voltage'
class: 'voltage'
state_class: 'measurement'
uom: 'V'
scale: 0.1
rule: 1
registers: [0x0587]
icon: 'mdi:sine-wave'
- name: 'PV1 Current'
class: 'current'
state_class: 'measurement'
uom: 'A'
scale: 0.01
rule: 1
registers: [0x0585]
icon: 'mdi:current-ac'
- name: 'PV2 Current'
class: 'current'
state_class: 'measurement'
uom: 'A'
scale: 0.01
rule: 1
registers: [0x0588]
icon: 'mdi:current-ac'
- group: Grid
items:
- name: 'Grid Frequency'
class: 'frequency'
state_class: 'measurement'
uom: 'Hz'
scale: 0.01
rule: 1
registers: [0x0484]
icon: 'mdi:home-lightning-bolt'
- name: 'Active Power Output Total'
class: 'power'
state_class: 'measurement'
uom: 'W'
scale: 10
rule: 2
registers: [0x0485]
icon: 'mdi:lightning-bolt'
- name: 'Active Power Output Total kW'
class: 'power'
state_class: 'measurement'
uom: 'kW'
scale: 0.01
rule: 2
registers: [0x0485]
icon: 'mdi:lightning-bolt'
- name: 'Voltage Phase R'
class: 'voltage'
state_class: 'measurement'
uom: 'V'
scale: 0.1
rule: 2
registers: [0x048D]
icon: 'mdi:sine-wave'
- name: 'Current Phase R'
class: 'current'
state_class: 'measurement'
uom: 'A'
scale: 0.01
rule: 2
registers: [0x048E]
icon: 'mdi:current-ac'
- name: 'Voltage Phase S'
class: 'voltage'
state_class: 'measurement'
uom: 'V'
scale: 0.1
rule: 2
registers: [0x0498]
icon: 'mdi:sine-wave'
- name: 'Current Phase S'
class: 'current'
state_class: 'measurement'
uom: 'A'
scale: 0.01
rule: 2
registers: [0x0499]
icon: 'mdi:current-ac'
- name: 'Voltage Phase T'
class: 'voltage'
state_class: 'measurement'
uom: 'V'
scale: 0.1
rule: 2
registers: [0x04A3]
icon: 'mdi:sine-wave'
- name: 'Current Phase T'
class: 'current'
state_class: 'measurement'
uom: 'A'
scale: 0.01
rule: 2
registers: [0x04A4]
icon: 'mdi:current-ac'
- group: Inverter
items:
- name: 'Inverter status'
class: ''
state_class: 'measurement'
uom: ''
scale: 1
rule: 1
registers: [0x0404]
lookup:
- key: 0
value: 'Stand-by'
- key: 1
value: 'Self-checking'
- key: 2
value: 'Normal'
- key: 3
value: 'FAULT'
- key: 4
value: 'Permanent'
icon: 'mdi:wrench'
- name: 'Module temperature'
class: 'temperature'
uom: '°C'
scale: 0.1
rule: 2
registers: [0x0683]
icon: 'mdi:thermometer'
- name: 'Ambient temperature'
class: 'temperature'
uom: '°C'
scale: 1
rule: 2
registers: [0x0418]
icon: 'mdi:thermometer'
- name: 'Radiator temperature'
class: 'temperature'
uom: '°C'
scale: 1
rule: 2
registers: [0x041A]
icon: 'mdi:thermometer'
- name: 'Insulation Resistance'
class: ''
state_class: 'measurement'
uom: 'Ω'
scale: 1
rule: 1
registers: [0x042B]
icon: 'mdi:omega'
- name: 'Generation time today'
class: ''
state_class: 'measurement'
uom: 'min'
scale: 1
rule: 1
registers: [0x0426]
icon: 'mdi:clock-time-nine-outline'
- name: 'Total generation time'
class: ''
state_class: 'measurement'
uom: 'min'
scale: 1
rule: 1
registers: [0x0428, 0x0427]
icon: 'mdi:clock-time-nine-outline'
- name: 'Total working time'
class: ''
state_class: 'measurement'
uom: 'min'
scale: 1
rule: 1
registers: [0x042A, 0x0429]
icon: 'mdi:clock-time-nine-outline'
- group: Alert
items:
- name: 'Alert'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 6
registers:
[
0x0405,
0x0406,
0x0407,
0x0408,
0x0409,
0x040A,
0x040B,
0x040C,
0x040D,
0x040E,
0x040F,
0x0410,
]
- name: 'Fault 1'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
registers: [0x0405]
isstr: true
icon: 'mdi:wrench'
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID01 Grid Over Voltage Protection'
- key: 2
value: 'ID02 Grid Under Voltage Protection'
- key: 4
value: 'ID03 Grid Over Frequency Protection'
- key: 8
value: 'ID04 Grid Under Frequency Protection'
- key: 16
value: 'ID05 Leakage current fault'
- key: 32
value: 'ID06 High penetration error'
- key: 64
value: 'ID07 Low penetration error'
- key: 128
value: 'ID08 Islanding error'
- key: 256
value: 'ID09 Grid voltage transient value overvoltage 1'
- key: 512
value: 'ID10 Grid voltage transient value overvoltage 2'
- key: 1024
value: 'ID11 Grid line voltage error'
- key: 2048
value: 'ID12 Inverter voltage error'
- key: 4096
value: 'ID13 Anti-backflow overload'
- key: 8192
value: 'ID14'
- key: 16384
value: 'ID15'
- key: 32768
value: 'ID16'
- name: 'Fault 2'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
isstr: true
registers: [0x0406]
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID17 Grid current sampling error'
- key: 2
value: 'ID18 Grid current DC component sampling error (AC side)'
- key: 4
value: 'ID19 Grid voltage sampling error (DC side)'
- key: 8
value: 'ID20 Grid voltage sampling error (AC side)'
- key: 16
value: 'ID21 Leakage current sampling error (DC side)'
- key: 32
value: 'ID22 Leakage current sampling error (AC side)'
- key: 64
value: 'ID23 Load voltage DC component sampling error'
- key: 128
value: 'ID24 DC input current sampling error'
- key: 256
value: 'ID25 DC component sampling error of grid current (DC side)'
- key: 512
value: 'ID26 DC input branch current sampling error'
- key: 1024
value: 'ID27'
- key: 2048
value: 'ID28'
- key: 4096
value: 'ID29 Leakage current consistency error'
- key: 8192
value: 'ID30 Grid voltage consistency error'
- key: 16384
value: 'ID31 DCI consistency error'
- key: 32768
value: 'ID32'
- name: 'Fault 3'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
isstr: true
registers: [0x0407]
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID033 SPI communication error (DC side)'
- key: 2
value: 'ID034 SPI communication error (AC side)'
- key: 4
value: 'ID035 Chip error (DC side)'
- key: 8
value: 'ID036 Chip error (AC side)'
- key: 16
value: 'ID037 Auxiliary power error'
- key: 32
value: 'ID038 Inverter soft start failure'
- key: 64
value: 'ID039 '
- key: 128
value: 'ID040 '
- key: 256
value: 'ID041 Relay detection failure'
- key: 512
value: 'ID042 Low insulation impedance'
- key: 1024
value: 'ID043 Grounding error'
- key: 2048
value: 'ID044 Input mode setting error'
- key: 4096
value: 'ID045 CT error'
- key: 8192
value: 'ID046 Input reversal error'
- key: 16384
value: 'ID047 Parallel error'
- key: 32768
value: 'ID048 Serial number error'
- name: 'Fault 4'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
registers: [0x0408]
isstr: true
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID049 Battery temperature protection'
- key: 2
value: 'ID050 Heat sink 1 temperature protection'
- key: 4
value: 'ID051 Heater 2 temperature protection'
- key: 8
value: 'ID052 Heater 3 temperature protection'
- key: 16
value: 'ID053 Heatsink 4 temperature protection'
- key: 32
value: 'ID054 Heatsink 5 temperature protection'
- key: 64
value: 'ID055 Radiator 6 temperature protection'
- key: 128
value: 'ID056 '
- key: 256
value: 'ID057 Ambient temperature 1 protection'
- key: 512
value: 'ID058 Ambient temperature 2 protection'
- key: 1024
value: 'ID059 Module 1 temperature protection'
- key: 2048
value: 'ID060 Module 2 temperature protection'
- key: 4096
value: 'ID061 Module 3 temperature protection'
- key: 8192
value: 'ID062 Module temperature difference is too large'
- key: 16384
value: 'ID063 '
- key: 32768
value: 'ID064 '
- name: 'Fault 5'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
registers: [0x0409]
isstr: true
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID065 Bus voltage RMS unbalance'
- key: 2
value: 'ID066 Bus voltage transient value unbalance'
- key: 4
value: 'ID067 Undervoltage of busbar during grid connection'
- key: 8
value: 'ID068 Bus bar low voltage'
- key: 16
value: 'ID069 PV overvoltage'
- key: 32
value: 'ID070 Battery over-voltage'
- key: 64
value: 'ID071 LLCBus overvoltage protection'
- key: 128
value: 'ID072 Inverter bus voltage RMS software overvoltage'
- key: 256
value: 'ID073 Inverter bus voltage transient value software overvoltage'
- key: 512
value: 'ID074 Flying Cross Capacitor Overvoltage Protection'
- key: 1024
value: 'ID075 Flying Cross capacitor undervoltage protection'
- key: 2048
value: 'ID076 '
- key: 4096
value: 'ID077 '
- key: 8192
value: 'ID078 '
- key: 16384
value: 'ID079 '
- key: 32768
value: 'ID080 '
- name: 'Fault 6'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
isstr: true
registers: [0x040A]
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID081 Battery overcurrent software protection'
- key: 2
value: 'ID082 Dci overcurrent protection'
- key: 4
value: 'ID083 Output transient current protection'
- key: 8
value: 'ID084 BuckBoost software overcurrent'
- key: 16
value: 'ID085 Output RMS current protection'
- key: 32
value: 'ID086 PV instantaneous current overcurrent software protection'
- key: 64
value: 'ID087 PV parallel uneven current'
- key: 128
value: 'ID088 Output current unbalance'
- key: 256
value: 'ID089 PV software overcurrent protection'
- key: 512
value: 'ID090 Balanced circuit overcurrent protection'
- key: 1024
value: 'ID091 Resonance protection'
- key: 2048
value: 'ID092 '
- key: 4096
value: 'ID093 '
- key: 8192
value: 'ID094 '
- key: 16384
value: 'ID095 '
- key: 32768
value: 'ID096 '
- name: 'Fault 7'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
isstr: true
registers: [0x040B]
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID097 LLC bus hardware overvoltage'
- key: 2
value: 'ID098 Inverter bus hardware overvoltage'
- key: 4
value: 'ID099 BuckBoost hardware overcurrent'
- key: 8
value: 'ID100 Battery hardware overcurrent'
- key: 16
value: 'ID101 '
- key: 32
value: 'ID102 PV hardware overcurrent'
- key: 64
value: 'ID103 AC output hardware overcurrent'
- key: 128
value: 'ID104 '
- key: 256
value: 'ID105 Power meter error'
- key: 512
value: 'ID106 Serial number model error'
- key: 1024
value: 'ID107 '
- key: 2048
value: 'ID108 '
- key: 4096
value: 'ID109 '
- key: 8192
value: 'ID110 Overload protection 1'
- key: 16384
value: 'ID111 Overload protection 2'
- key: 32768
value: 'ID112 Overload protection 3'
- name: 'Fault 8'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
registers: [0x040C]
isstr: true
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID113 Overtemperature derating'
- key: 2
value: 'ID114 Frequency down load'
- key: 4
value: 'ID115 Frequency loading'
- key: 8
value: 'ID116 Voltage down load'
- key: 16
value: 'ID117 Voltage loading'
- key: 32
value: 'ID118 '
- key: 64
value: 'ID119 '
- key: 128
value: 'ID120 '
- key: 256
value: 'ID121 Lightning protection failure (DC)'
- key: 512
value: 'ID122 Lightning protection failure (AC)'
- key: 1024
value: 'ID123 '
- key: 2048
value: 'ID124 Battery low voltage protection'
- key: 4096
value: 'ID125 Battery low voltage shutdown'
- key: 8192
value: 'ID126 Battery low voltage pre-alarm'
- key: 16384
value: 'ID127 '
- key: 32768
value: 'ID128 '
- name: 'Fault 9'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
isstr: true
registers: [0x040D]
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID129 Output hardware overcurrent permanent fault'
- key: 2
value: 'ID130 Bus overvoltage permanent fault'
- key: 4
value: 'ID131 Bus hardware over-voltage permanent fault'
- key: 8
value: 'ID132 PV uneven flow permanent fault'
- key: 16
value: 'ID133 Battery overcurrent permanent fault in EPS mode'
- key: 32
value: 'ID134 Output transient overcurrent permanent fault'
- key: 64
value: 'ID135 Output current unbalance permanent fault'
- key: 128
value: 'ID136 '
- key: 256
value: 'ID137 Input mode setting error permanent fault'
- key: 512
value: 'ID138 Input overcurrent permanent fault'
- key: 1024
value: 'ID139 Input hardware overcurrent permanent fault'
- key: 2048
value: 'ID140 Relay permanent fault'
- key: 4096
value: 'ID141 Bus unbalance permanent fault'
- key: 8192
value: 'ID142 Lightning protection permanent fault - DC side'
- key: 16384
value: 'ID143 Lightning protection permanent fault - AC side'
- key: 32768
value: 'ID144 '
- name: 'Fault 10'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
isstr: true
registers: [0x040E]
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID145 USB fault'
- key: 2
value: 'ID146 WIFI fault'
- key: 4
value: 'ID147 Bluetooth fault'
- key: 8
value: 'ID148 RTC clock fault'
- key: 16
value: 'ID149 Communication board EEPROM error'
- key: 32
value: 'ID150 Communication board FLASH error'
- key: 64
value: 'ID151 '
- key: 128
value: 'ID152 Safety regulation version error'
- key: 256
value: 'ID153 SCI communication error (DC side)'
- key: 512
value: 'ID154 SCI communication error (AC side)'
- key: 1024
value: 'ID155 SCI communication error (convergence board side)'
- key: 2048
value: 'ID156 Software version inconsistency'
- key: 4096
value: 'ID157 Lithium battery 1 communication error'
- key: 8192
value: 'ID158 Li-ion battery 2 communication error'
- key: 16384
value: 'ID159 Lithium battery 3 communication error'
- key: 32768
value: 'ID160 Lithium battery 4 communication failure'
- name: 'Fault 11'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
registers: [0x040F]
isstr: true
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID161 Forced shutdown'
- key: 2
value: 'ID162 Remote shutdown'
- key: 4
value: 'ID163 Drms0 shutdown'
- key: 8
value: 'ID164 '
- key: 16
value: 'ID165 Remote down load'
- key: 32
value: 'ID166 Logic interface down load'
- key: 64
value: 'ID167 Anti-Reverse Flow Downgrade'
- key: 128
value: 'ID168 '
- key: 256
value: 'ID169 Fan 1 failure'
- key: 512
value: 'ID170 Fan 2 failure'
- key: 1024
value: 'ID171 Fan 3 failure'
- key: 2048
value: 'ID172 Fan 4 failure'
- key: 4096
value: 'ID173 Fan 5 failure'
- key: 8192
value: 'ID174 Fan 6 failure'
- key: 16384
value: 'ID175 Fan 7 fault'
- key: 32768
value: 'ID176 Meter communication failure'
- name: 'Fault 12'
class: ''
state_class: ''
uom: ''
scale: 1
rule: 1
icon: 'mdi:wrench'
registers: [0x0410]
isstr: true
lookup:
- key: 0
value: 'No error'
- key: 1
value: 'ID177 BMS over-voltage alarm'
- key: 2
value: 'ID178 BMS undervoltage alarm'
- key: 4
value: 'ID179 BMS high temperature alarm'
- key: 8
value: 'ID180 BMS low temperature alarm'
- key: 16
value: 'ID181 BMS charge/discharge overload alarm'
- key: 32
value: 'ID182 BMS short circuit alarm'
- key: 64
value: 'ID183 BMS version inconsistency'
- key: 128
value: 'ID184 BMS CAN version inconsistency'
- key: 256
value: 'ID185 BMS CAN version is too low'
- key: 512
value: 'ID186 '
- key: 1024
value: 'ID187 '
- key: 2048
value: 'ID188 '
- key: 4096
value: 'ID189 Arc device communication failure'
- key: 8192
value: 'ID190 DC arc alarm fault'
- key: 16384
value: 'ID191 PID repair failed'
- key: 32768
value: 'ID192 PLC module heartbeat loss'
Also add an entry ( 'sofar_ktl_x_g3.yaml', ) in the const.py file
from datetime import timedelta
DOMAIN = 'solarman'
DEFAULT_PORT_INVERTER = 8899
DEFAULT_INVERTER_MB_SLAVEID = 1
DEFAULT_LOOKUP_FILE = 'deye_hybrid.yaml'
LOOKUP_FILES = [
'deye_2mppt.yaml',
'deye_4mppt.yaml',
'deye_hybrid.yaml',
'deye_sg04lp3.yaml',
'deye_string.yaml',
'kstar_hybrid.yaml',
'sofar_g3hyd.yaml',
'sofar_hyd3k-6k-es.yaml',
'sofar_ktl_x_g3.yaml',
'sofar_lsw3.yaml',
'sofar_wifikit.yaml',
'solis_1p8k-5g.yaml',
'solis_3p-4g.yaml',
'solis_hybrid.yaml',
'solis_s6-gr1p.yaml',
'zcs_azzurro-ktl-v3.yaml',
'custom_parameters.yaml'
]
MIN_TIME_BETWEEN_UPDATES = timedelta(seconds=15)
CONF_INVERTER_HOST = 'inverter_host'
CONF_INVERTER_PORT = 'inverter_port'
CONF_INVERTER_SERIAL = 'inverter_serial'
CONF_INVERTER_MB_SLAVEID = 'inverter_mb_slaveid'
CONF_LOOKUP_FILE = 'lookup_file'
SENSOR_PREFIX = 'Solarman'
Version 1.5.0 has a breaking change - the modbus protocol implementation using pysolarmanv5 module instead of internal one existing in previous versions.
I don't understand, in general it means it won't work on some inverters now?
Yes, It may not work at all or work partially. In my case the stick (LSW3_15_270A_1.50) is buggy and pysolarmanv5 is working somehow but keep crashing threads of Home Assistant and generates a lot of mess into log. I decided to revert to older "local implementation" found in version < 1.5.0
@jmccrohan, Any idea?