OrcaSlicer icon indicating copy to clipboard operation
OrcaSlicer copied to clipboard

Update 0.48mm Standard @BBL X1C 0.8 nozzle.json

Open SufficentMuffin opened this issue 1 year ago • 2 comments

Removed P1S 0.6mm nozzle from process profile.

SufficentMuffin avatar Dec 30 '23 21:12 SufficentMuffin

Hi,

Can you provide some description/explain for the change?

SoftFever avatar Dec 31 '23 11:12 SoftFever

Of course, please excuse.

If you choose Bambu´s P1S with the 0.6 mm nozzle the Slicer will show the 0.48 mm layer height profile for it. This should not be the case since the max layer height for 0.6 mm nozzle is 0.42 mm. If you choose the 0.48mm profile and slice an object it will throw an "error" whichs says the layer height was changed back to 0.42mm.

SufficentMuffin avatar Dec 31 '23 11:12 SufficentMuffin

Of course, please excuse.

If you choose Bambu´s P1S with the 0.6 mm nozzle the Slicer will show the 0.48 mm layer height profile for it. This should not be the case since the max layer height for 0.6 mm nozzle is 0.42 mm. If you choose the 0.48mm profile and slice an object it will throw an "error" whichs says the layer height was changed back to 0.42mm.

Thanks for the info and nice catch. I think in this case, it would be better to change it to Bambu Lab P1S 0.8 nozzle.

SoftFever avatar Jan 01 '24 04:01 SoftFever

Sorry if I confused you.

I don't want to print with 0.48 mm layer height.

I just wanted to point out that it's not correct that you can choose 0.48mm while 0.6mm nozzle is active. That's why I removed the line from the code.

SufficentMuffin avatar Jan 01 '24 05:01 SufficentMuffin

I can provide some screenshots later to make it more clear :)

SufficentMuffin avatar Jan 01 '24 05:01 SufficentMuffin

Sorry if I confused you.

I don't want to print with 0.48 mm layer height.

I just wanted to point out that it's not correct that you can choose 0.48mm while 0.6mm nozzle is active. That's why I removed the line from the code.

Let me clarify what I meant. The 0.48mm process profile is meant for 0.8mm nozzle. P1S 0.6 nozzle machines shouldn't see this process. Which your PR is aiming to fix. What I suggested change it to P1S 0.8 nozzle as it is intended for. You can see X1/X1C/X1E are correct here image

SoftFever avatar Jan 01 '24 05:01 SoftFever