Actually it is related to https://github.com/jsdoc2md/jsdoc-to-markdown/issues/112 i think. So i guess if you are able to set the line ending it should be fine. Will try to put together a...

@Louisvdw this sounds a bit complex but a few things can be made easier, like that you do not need to manually setup can0, if i add the right filters...

I just added the can filters, so no need to manually set up can anymore as it is set to 250k by default, we can still mention to check if...

Daly has 250k. If the MP2 GX has VE.Can it can be configured to 250k. Only BMS Can is 500k.

Daly has CAN bus so i just connected pins L and H from Daly to can port from Cerbo.

@chavalaloco i had to press the BT button before i could communicate with the dongle. The BMS goes into standby on UART after a while and on start. So when...

Seplos supports connection to Victron out of the box via can bus, no need to support here.

Hm looks like CAN on daly is a gamble as noone really knows if they have CAN or not. Read from some guys, that only RS485 is available but not...

How did you know CAN was working if you could not see anything except counting packages? As soon as you connect, Venus OS sends out messages on CAN that fit...

Ok can now connect to Daly BMS via canbus. Here a sample for cells voltage: ``` candump can0 can0 18950140 [0] can0 18954001 [8] 01 0D 7D 0D 7E 0D...