ENH: `LineParameters` alternative constructors
In #121, I realized several things that should be done regarding the LineParameters
class. Here is a small list of remaining tasks
- [ ] In the class method
from_geometry
, there is a geometric configuration for a twisted line and for an underground line. There is no configuration for overhead line (flag configuration for example). Currently, the overhead is linked to the twisted configuration. - [x] In the class method
from_geometry
, some checks should be done:- [x] with an underground line, the
height
parameter should be negative. For overhead and twisted lines,height
should be positive - [x] when the sections become large, there is some geometric infeasibility because of the
d_{ext}/4
constraint (especially in the twisted configuration) => Maybe modify the provided lengths/dimensions to ensure that no impossible configurations can be generated.
- [x] with an underground line, the
- [ ] In the class method
from_geometry
, if no neutral data are provided, maybe consider generating configuration without neutral wire (3x3 matrices). Or take a new "phases" argument to define the number of conductors in the geometric configuration. - [ ] The class method
from_name_mv
uses the Coiffier's coefficients to generate the impedance and shunt admittance matrices. It needs to be refactor in a more interesting name. The documentation doesn't exist... - [x] The class method
from_name_lv
is a wrapper around thefrom_geometry
class method with default values. I think it should be removed.